Warnings
TPOne monitors several conditions and will provide warnings when
necessary, these messages will be shown at the top of the display.
If the condition that has created the warning has been corrected
then the message can be cancelled by selecting Clear Warnings
in the TPOne menu. Where more than one warning has occurred
the most recent will be shown on the display. All warnings can be
viewed and cleared in the Clear Warnings menu.
RF Lost
If the RF connection between the TPOne-RF and
Receiver has been lost this warning will be shown.
If this warning is shown and the RF Icon is still
displayed on the TPOne-RF the loss of connection
may have only been temporary and re-connection
was made automatically. The warning can then be
cleared in the menu. If the RF Icon is not displayed
then connection may not be possible or may be
inconsistant.
Important Note: Ensure that there are no large metal
objects, such as boiler cases, other large appliances
or mirrors in line of sight between the transmitter and
receiver as these will prevent communication between
the TPOne-RF and receiver.
Pairing
Failed
When first installed the startup Wizard will include
the pairing of the TPOne-RF and the Receiver. If
this function was not completed correctly or failed
due to unreliable connection then this warning
will be shown. Manual pairing can be made by
selecting this option in the installer menu.
Important Note: Ensure that there are no large metal
objects, such as boiler cases, other large appliances
or mirrors in line of sight between the transmitter and
receiver as these will prevent communication between
the TPOne-RF and receiver.
Frost Risk
Low Heat
This will be displayed if the TPOne monitors a
temperature of below 5oC. TPOne will call for
heat if this occurs but if the heat source is faulty
then risk of frost damage may still occur. The
heating system should be checked to confirm it is
operating correctly
If set mode temperature is not reached within
2 hours then TPOne will warn of Low Heat. The
heating system should be checked to confirm it is
operating correctly
Danfoss Heating
25
| General | Details |
|---|---|
| Name | Danfoss TPOne-RF Electronic Programmable Room Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.42 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide