Ouellet Canada OTH24-AFR Programmable Low Voltage Electronic Thermostat User Guide

8. Second output cycle length  
Select the cycle length according to the connected load  
OFF, 15 seconds, 5, 10, 15, 20, 25, 30 minutes.  
INSTALLATION  
3. If lock mode is activated, you will need to enter a  
4-digit code.  
Installation and Programming Guide  
Programmable Low Voltage  
Electronic Thermostat  
As you are a valuable Ouellet Canada Inc. customer, we ask  
that you please cut the power to the heating system from  
the main power panel to avoid any risk of electric shocks.  
OTH24-AFR  
The 15-seconds cycle should only be used if an electronic  
relay (SSR) activates the load  
(Default: OFF).  
Using a square or flat screwdriver, loosen the screw a quar-  
ter turn and separate the thermostat faceplate.  
CONNECTING YOUR THERMOSTAT  
Insert each wire into its terminal according to the heating  
system and screw firmly. (See connection layouts outlined  
below.)  
4. In lock mode only:  
Low temperature limit for heated floor only  
(Default: 5 °C).  
9. Minimum Time ON  
Defines the minimum time for which the output can  
be turned ON  
Connection of the floor sensor (optional)  
Used for gaz or oil system with a purge. The ON time  
should not be shorter than the purge time.  
0, 30 seconds, 1, 2, 3, 4, 5 minutes  
(Default: 0).  
MAIN CONFIGURATION MENU FOR INSTALLER  
1. Press simultaneously the Menu button and the second-to-  
last button (Next) and hold for 5 seconds to access the  
installer settings.  
2. Press Up or Down to change the setting displayed.  
3. Press Next to go forward or Back to go back.  
PARTS INCLUDED  
4. Return  
to exit the configuration menu.  
5. In lock mode only:  
High temperature limit for heated floor only  
(Default: 36 °C).  
Connection layout for an electric baseboard  
One (1) thermostat  
Two (2) 6-32 mounting screws  
Two (2) wall anchors  
INSTALLER SETTINGS DISPLAY ORDER  
10. Minimum Time OFF  
Defines the minimum time for which the output can  
be turned OFF  
1. User interface selection:  
Programmable 7 days (7), Programmable 5/2 days (5/2), or  
Non programmable (NP) (Default: 7 days).  
ABOUT YOUR THERMOSTAT  
The OTH24-AFR programmable low voltage electronic  
thermostat is designed to control any 24-Vac heating load.  
It has a terminal to connect a temperature sensor to read the  
floor temperature. (Floor temperature sensor not included.)  
0, 30 seconds, 1, 2, 3, 4, 5 minutes  
(Default: 0).  
The thermostat has two (2) low-voltage outputs that can  
be connected using a 24-volt relay and a transformer to  
control electric baseboard heaters, convectors (short cycle)  
or forced-air convectors (long cycle), electric heating floors,  
water pumps and boilers.  
6. Thermostat control mode, choose between 3 modes:  
A (Air) controls using the built-in air sensor of the  
thermostat, F (Floor) controls using the optional floor sensor  
and P (proportional) controls using a fixed duty cycle  
without using the temperature sensors.  
Connection layout for an electric floor heating with  
electric baseboard on the 2nd heating stage  
IMPORTANT: If the “Non programmable” interface is selected  
in the installer settings, the time and programming schedule  
menus will no longer be available.  
The thermostat can run using a single output or two (2)  
outputs. When two outputs are used, if the first output  
cannot control the heating system to reach the desired  
setpoint, then the second output will be activated. This is  
ideal for rooms where the floor is the main heating element  
and a second heating element is used for colder days, like a  
baseboard under the window.  
(Default: A).  
MAIN USER CONFIGURATION MENU  
2. Keypad lock activation (Default: O). If the keypad is not  
locked, skip to Step 6.  
normally closed  
Boost/Time  
Fan/Day  
Both outputs control cycle length can be configured separa-  
tely. For example, the floor heating system could be on  
a 15-minutes cycle using a mechanical relay and the base-  
board would be on a 15-seconds cycle using an electronic  
relay (SSR).  
Back/PreSet  
Next/Pgm  
Menu/  
Up  
7. Main output cycle length  
Select the cycle length according to the connected load  
15 seconds, 5, 10, 15, 20, 25, 30 minutes.  
Down  
The thermostat can also be used in proportional mode,  
where it applies a fixed duty cycle to its output.  
Three (3) options possible:  
• OFF: No lock.  
Connection layout for a hot water valve  
• INST: Installer menu locked, but all other functions are  
accessible and the setpoint is limited by lock min/max.  
• ALL: Keypad is fully locked.  
The 15-seconds cycle should only be used if an electronic  
relay (SSR) activates the load  
(Default: 15 minutes).  
Same programming for all modes  
1. Press and hold Menu for 5 seconds to access user  
settings.  
2. Press Up or Down to change displayed setting.  
3. Press Next to go forward or Back to go back.  
IMPORTANT: When the lock option is activated, all thermostat  
functions are deactivated except temperature adjustments  
within the range allotted in the installer menu. The word  
“LOCK” appears briefly onscreen when a button is pressed.  
In lock mode it is impossible to access the installer menu  
without the 4-digit code.  
4. Press Return  
to exit the configuration menu.  
Note: The thermostat will automatically save all changes  
and return to the regular display if no button is pressed  
for 1 minute.  
GeneralDetails
NameOuellet Canada OTH24-AFR Programmable Low Voltage Electronic Thermostat User Guide
MakeOuellet Canada
LanguageEnglish
FiletypePDF (Download)
File size0.23 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Ouellet Canada OTH24-AFR Programmable Low Voltage Electronic Thermostat User Guide
Get the free PDF manual for the Ouellet Canada OTH24-AFR Programmable Low Voltage Electronic Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Ouellet Canada OTH24-AFR Programmable Low Voltage Electronic Thermostat User Guide Overview

Summary of Contents

  • Page 1: output cycle length Select the cycle length according to the connected load. If lock mode is activated, you will need to enter a 4-digit code. Cut the power to the heating system from the main power panel to avoid any risk of electric shocks. The 15-seconds cycle should only be used if an electronic relay (SSR) activates the load. Insert each wire into its terminal according to the heating system and screw firmly. Minimum time ON defines the minimum time for which the output can be turned ON. User interface selection: Programmable 7 days, Programmable 5/2 days, or Non-programmable. The OTH24-AFR programmable low voltage electronic thermostat is designed to control any 24-Vac heating load. The thermostat has two low-voltage outputs that can be connected using a 24-volt relay and a transformer. IMPORTANT: When the lock option is activated, all thermostat functions are deactivated except temperature adjustments.
  • Page 2: Floor temperature limit maximum: 5 °C to 36 °C (Default: OFF). Floor temperature limit minimum: 5 °C to 36 °C (Default: OFF). In the event of a power failure, the screen will turn off and your settings will be saved. If the power failure exceeds 8 hours, you will have to reset the time and date. A floor sensor must be installed to access the minimum and maximum floor temperature limits. Error codes indicate various issues with the thermostat temperature sensors. The thermostat features two different programming methods: 5-2 and 7. The Boost mode is only available in Ambient mode and proportional mode. The manufacturer warrants the components of the product against defects for a three-year period. If no heating is required, you can put the thermostat in Sleep mode.