CENTER EHE0200123 Wired 7 Day Programmable Thermostat Installation Guide
Installation Guide
340023 (EHE0200123)
Wired 7 Day Programmable Thermostat
IMPORTANT: Please read these instructions fully prior to use
as they contain information that will help get the best from
your wired thermostat, ensuring it is operating correctly and
safely.
If during the installation or set up you experience any issues
please call 0344 292 7060 for assistance.
Must be installed by a competent person.
To ensure your safety make sure the mains
power is switched OFF before accessing wiring.
To prevent a short circuit from a loose wire:
Contents
•
Multi-core cables: Only remove enough outer insulation
to allow secure fixing of the cores into the terminal block.
Single core cables: Secure them together with a cable tie
as close as possible to the terminal block.
Thermostat
Accessories
2 x AA LR6
Instructions
•
Install the Thermostat
1
2
= M3.5
= N°6
B
B
3
4
ON
1.2-1.5m
Wiring
On/off boiler (230V)
Combi boiler
2-Port Zone Valve
Thermostat
Thermostat
Thermostat
3(1)A
3(1)A
3(1)A
S
S
T
T
A
B
C
S
S
T
T
A
B
C
S
S
T
T
A
B
C
T1 T2
Permanent Live
not required
Combi-
Boiler
V4043
Zone Valve
Basic Boiler
| General | Details |
|---|---|
| Name | CENTER EHE0200123 Wired 7 Day Programmable Thermostat Installation Guide |
| Make | CENTER |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.16 MB |

CENTER EHE0200322 RF Wireless 7 Day Programmable Thermostat Installation Guide

EHE0200123 Manual: Questions and Answers
Can the EHE0200123 thermostat work with a 2-port zone valve?
Yes. The thermostat has a dedicated wiring configuration for 2-port zone valves, with terminals S, ST and T connecting to the V4043 zone valve. Installation Guide, p. 1
What is the temperature range for the EHE0200123 lower limit setting?
5 to 21 °C. Installation Guide, p. 2