Danfoss RET2001OT Digital Open Therm Room Thermostat User Guide
User Guide
RET2001OT Digital OpenTherm™ Room Thermostat
6
Select Away Mode
•
•
•
Press M to enter Away mode and
will be displayed.
Away mode temperature can be set in parameter settings, P07.
Press M again to exit Away mode.
7
Set Control Parameters
Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set the
parameter range via < or >. Complete all adjustments.
To exit press upper part of setting ring or wait 20secs for automatic exit.
The digits indicate the set value as follows:
No.
Parameter settings
Settings range
Between low (P05) and 35 °C
Between 5 °C and high (P04)
Between 5 °C and 15 °C
Default
35 °C
5 °C
P04 Temperature limit high
P05 Temperature limit low
P06 Frost protect temperature
P07 Away mode temperature
5 °C
Between low (P05) and high (P04)
18 °C
8
Error Messages
E1
EE
Lo
Hi
Sensor failure
EEPROM failure
Measured temperature below 0 °C
Measured temperature above 50 °C
All relay output will be turned off in all cases.
Danfoss Heating
3
VUSUE102
09/2020
| General | Details |
|---|---|
| Name | Danfoss RET2001OT Digital Open Therm Room Thermostat User Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.18 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide