Danfoss ECtemp Smart Intelligent Electronic Timer Thermostat Installation Guide
Danfoss ECtemp™ Smart
Ambient temperature
0 ° to +30 °C
Frost protection
temperature
5 °C to +9 °C (default 5 °C)
Temperature range
Room temperature: 5-35 °C.
Floor temperature: 5-45 °C.
Max. floor: 20-35 °C (if unrecov-
erable seal is broken then up to
45 °C). Min. floor: 10-35 °C, only
with combination of room and
floor sensor.
Sensor failure monitoring
Cable specification max.
The thermostat has a built-in
monitoring circuit, which will
switch off the heating if the
sensor is disconnected or short-
circuited
1x4 mm2
Ball pressure test temperature 75 °C
Pollution degree
Controller type
Software class
Storage temperature
IP class
2 (domestic use)
1C
A
-20 °C to +65 °C
21
Protection class
Class II -
Installation Guide
5
| General | Details |
|---|---|
| Name | Danfoss ECtemp Smart Intelligent Electronic Timer Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.53 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide