Danfoss ECtemp 132 Electronic Thermostat Installation Guide
ECtemp 132
1.1 Technical Specifications
Operation voltage
220-240 V~, 50 Hz
Max 5 W
Standby power consump-
tion
Relay:
Resistive load
Inductive load
Max 16 A / 3680 W @ 230 V
cos φ= 0.3 max 1 A
Sensing units
NTC 15 kOhm at 25 °C
Sensing values:
0 °C
25 °C
42 kOhm
15 kOhm
6 kOhm
50 °C
Hysteresis
0,2 °C
0 to +30 °C
5 °C -
Ambient temperature
Frost protection temperature
5-35 °C room temperature
20-50 °C floor temperature
limiter - default 35 °C
Temperature range
1x4 mm² or 2x2,5 mm²
Cable specification max
Ball pressure temperature
Pollution degree
75 °C
Degree 2 (domestic use)
Type
1C
Storage temperature
-20 to +65°C
4