Home > COLDBUSTER > COLDBUSTER MCD5 Programmable Thermostat User Manual

COLDBUSTER MCD5 Programmable Thermostat User Manual

CHILD LOCK:  
Enable Child Lock: Press main menu button, press USER settings.  
The 1st option at the top is CHILD LOCK. Press on CHILD LOCK. What  
appears is a digital slide switch. See image on the right. Press on the right-  
hand side of OFF. It should now say ON. To confirm this setting press the  
button on the lower right corner of the screen. It will now revert to User  
Options.  
Press the Left(back) button twice to get back to the Default Screen Page.  
The child lock will be activated after about 2 minutes when the screen saver  
activates. The image on the right is what you’ll get if you touch the screen  
saver  
DISABLE Child Lock: With the child lock screen activated, i.e., the  
“3 hotplates” appear. See image to the right.  
Draw an Lon the screen in a single stroke without lifting your finger  
from the screen. Start by touching the dot in the circle in the upper left  
corner, then slide your finger downwards to the dot in the circle in the lower  
left corner and continue sliding your finger to the dot in the circle in the lower  
right corner, forming an L.  
If done correctly, the home screen will appear.  
Please note that the child lock will be reactivated when the thermostat  
returns to screen saver mode unless it is deactivated in the menu: User  
Settings/Child Lock. i.e., do as above in Enable Child Lock, but now just tap to the left of ON etc.  
ADAPTIVE FUNCTION:  
The thermostat has the ADAPTIVE FUNCTION defaulted too ON.  
Adaptive Function is a setting that enables the thermostat to switch on prior to the set time to be warm by  
the set time. The thermostat has intuitive technology, which, as it knows what the floor temp is & what the  
time is. It can work out the rate of temperature change and thus switch on at the appropriate time  
beforehand so that it will be at the temp as set in the programming schedule at that scheduled time.  
This a very handy feature when in “Floor” sensor mode. Please be aware if you have the Adaptive Function  
on & set your thermostat to Room Limit or Room sensor mode this could dramatically  
increase you running costs  
Press main MENU button, Scroll down and press ENGINEER settings.  
It’s the 1st option. Tap on it.  
To switch Adaptive Function OFF. Tap the grey area to the left of ON.  
Do the opposite should you wish to turn it ON.  
ENERGY USE  
The thermostat has a section on how much your floor heating is costing you to run.  
Press the MENU button & then Energy Use button.  
It will bring up the 7-day usage graph. Tap on the  
arrow button.  
This gives you a breakdown of KWh & Price for the last Week, Month & Year.  
Should your thermostat be switching on heating to a large floor area, you could be  
getting inaccurate readings. Please contact CB to assist you here.  
The thermostat calculates the energy use based on a fixed electrical tariff. Should  
your home have a “smart” electricity meter, which charges different tariffs for  
electricity consumption at different times of the day and hence will not be providing an  
accurate running cost.  
If you keep on scrolling through the energy use page there will also be a running cost graph for last month  
& last year. The graph is indicating hour on per day.  
GeneralDetails
NameCOLDBUSTER MCD5 Programmable Thermostat User Manual
MakeCOLDBUSTER
LanguageEnglish
FiletypePDF (Download)
File size0.16 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COLDBUSTER MWD5 Programmable Thermostat User Manual
COLDBUSTER MWD5 Programmable Thermostat User Manual
RTH21 Programmable Thermostat Coldbuster Dual Instruction Manual
RTH21 Programmable Thermostat Coldbuster Dual Instruction Manual
COLDBUSTER CB Dual Thermostat User Manual
COLDBUSTER CB Dual Thermostat User Manual

COLDBUSTER MCD5 Programmable Thermostat User Manual