Beca BHT-7000 Smart Knob Thermostat User Manual
TECHNICAL DATA
Power Supply:95 ~240 VAC, 50~60Hz or 24V DC/AC, 50~60Hz
Please check the information laser printed on the back of the thermostat
for the actual voltage.
OPERATION
During Power On
WIRING
BHT-7000 Smart Knob Thermostat
GA
Please check the information laser printed on
the back of the thermostat for the actual voltage.
Electrical Shock or Equipment Damage
Hazard. Can shock individuals orshort
equipment circuitry.
AC95~240V
1. Press the home screen to enter the control interface.
2. Rotate the control interface to select
WIFI Type
N
L
NTC
IP20
M
Current Load: 5A (water heating, gas boiler), 16A (electric heating)
Sensor: NTC3950, 10K
CAUTION
Disconnect power supply before installation.
5
6
GB
3. Press the control interface to confirm
1
3
4
2
Accuracy: ±1°C
AC95~240V
Set Temp. Range: 5-35°C
4. Long press the control interface to return the home screen
N
L
NTC
Room Temp. Range: 5-99°C
IP20
LOAD
Display Temp. Range: 5 ~ 99°C
Ambient Temp.: 0~ 45°C
N1
2
L1
1
5
6
GC
4
3
Ambient Humidity: 5 ~ 95 % RH (Non Condensing)
Storage Temp.:-10~ 45°C
Power Consumption: <1. 5W
Timing Error: < 1%
HOME SCREEN QUICK REFERENCE
Weather
1. Power
AC95~240V
ON: The thermostat is controlling the heating device.
OFF: The thermostat stops controlling the heating device.
N
L
NTC
IP20
Dry Contact
Note:
Shell Material: PC +ABS ( Fireproof)
Installation Box: 86 * 86mm Square or European 60mm Round Box
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2
Protection Class: IP20
GA is for water heating;
2. Sensor types
1
3
4
GB is for electric heating;
GC is for water/gas boiler;
NTC and Modbus is optional.
2
In: Internal Sensor(to control the temp.)
Ou: External Sensor(to control the temp.)
AL: Internal/External Sensor (Internal sensor to
control the temp., external sensor to limit the temp.)
For Water Heating/Boiler/Electric Heating
Buttons: Capacitive Touch Buttons
New heating thermostat with knob BHT-7000
Six characteristics on the design
INSTALLATION
Your thermostat is suitable for istallation within a standard 86mm pattress
box or European 60mm pattress box.
3. Clock
DIMENSION: (mm)
60.0
Heating
Clock setting, the wifi version will automatically synchronize
the local time after networking.
℃
*1.32 inch circular and 240*240 TFT shows your artistic taste.
*Superfine aluminum side knob lets your fingers feel delicate.
44%
Outdoor Humidity
Mode
Step 1. Keep power off. See Fig 1.
Step 2. Remove the mounting plate by pushing the display assembly. See Fig 2.
4. Brightness
28.
5
Standby screen brightness setting. When set to 0, the screen will
turn off the display.
*Above 6H tempered glass keeps your screen away from
scratches.
1
Week
24:44
5. Mode
86.0
*Agile push button gives you an excellent experience.
*Seven colors ambient light increase color to your life.
Manual Mode
Programming mode (Schedule mode.)
46.2±0.3
32.4(显示区)
Clock
6. WiFi
*Variety brushed back panel options are suitable for different
home styles.
ON: The thermostat is in the wifi distribution network state.
OFF: The thermostat is not in the wifi distribution network state.
Note: The weather and humidity will be synchronized within 1 hour after the
device is connected to the Internet for the first time, and the weather
will be synchronized every hour thereafter.
27.0
16.7
Step 3. Connect power supply, load into the appropriate terminals.
(see "Wiring your thermostat" for details).
Step 4. Fix the mounting plate into the wall with screws inthe box(Fig 4).
7. Temp calibration
Please perform temperature correction after the thermostat has
been working for 30 minutes.
ABOUT YOUR THERMOSTATS
240RGB*240
1.3// TFT
The BHT-7000 range has been developed to control electric
underfloor, water heating or water/ gas boiler systems. These units
are designed for use in commercial, industrial, civil and domestic
properties
Main control interface
8. Set temp.
Set temperature range 5~45℃
Set week program on your App
Default settings for program schedule
Power
Set temp.
Mode
MODEL DEFINITION
GA: Water heating, 5A
GB: Electric floor Heating, 16A
GC: Water/Gas Boiler, 5A
L: Backlight
N: Modbus Communication
W: Wifi
S2: Both internal sensor and floor external sensor
Fig 3
Fig 4
WEEKDAY (MONDAY一FRIDAY)
(1 2 3 4 5 shows on screen)
WEEKEND (SATURDAY)
(6 shows on screen)
WEEKEND (SUNDAY)
(7 shows on screen)
Sensor types
Time display
Step 5. Fix the thermostat body and the mounting plate by the
lower button(Fig 5).
Step 6. Installation complete(Fig 6).
TIME
TEMPERATURE
20 ℃
TIME
TEMPERATURE
TIME
TEMPERATURE
Period 1
Period 2
06:00
08:00
11:30
13:30
17:00
06:00
08:00
11:30
13:30
17:00
20 ℃
20 ℃
20 ℃
20 ℃
20 ℃
06:00
08:00
11:30
13:30
17:00
22:00
20 ℃
20 ℃
20 ℃
20 ℃
20 ℃
15 ℃
BEFORE WIRING AND INSTALLING
Clock
WiFi
Period 3
Period 4
Period 5(1+2)
15 ℃
15 ℃
22 ℃
For example: BHT-7000GA
1. Read these instructions carefully. Failure to follow them could damage
the product or cause a hazardous condition.
Brightness
Temp calibration
22:00
Period 6(3+4)
15 ℃
15 ℃
15 ℃
22:00
2. Check the rathings given in the instructions and on the product to
make sure the product is suitable for your application.
3. Installer must be a trained, experienced service technician.
4. After installation is complete, check out product operation as provided
in these instructions.
In the box you will find
Thermostat
User Guide
QC Passed
1pc
1pc
1pc
Screws
2pc
1pc
A separate schedule may be set for weekdays (Mon – Fri) and
for weekends (Sat or Sun).
Wall plate
(Floor sensor is Optional)
Fig 6
Fig 5
Tip: Press the screen to enter the Main control interface.
| General | Details |
|---|---|
| Name | Beca BHT-7000 Smart Knob Thermostat User Manual |
| Make | BECA |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.65 MB |

Beca BHT-9000 Thermostat User Guide

beca BAC-005 Series Thermostat User Guide

Beca BHT-6000 Series Round Thermostat User Guide

Beca BAC-1000 Series WiFi Thermostat User Guide

Beca BHT-002 Electric Heating Wifi Thermostat User Guide

Beca BHT-008 Heating Thermostat User Guide

Beca BAC-006 Zigbee Thermostat User Guide

Beca BHT-006 Series Thermostat User Manual

Beca BHP-8000 C Room Thermostat User Guide

beca BAC-003 Series WiFi Thermostat Fan Coil User Guide

Beca BHT-7000 Smart Knob Thermostat User Manual Overview
Summary of Contents
- Page 1: Power supply: 95 ~240 VAC, 50~60Hz or 24V DC/AC, 50~60Hz. Current load: 5A (water heating, gas boiler), 16A (electric heating). Set temperature range: 5-35°C. Room temperature range: 5-99°C. Ambient temperature: 0~ 45°C. Ambient humidity: 5 ~ 95 % RH (non-condensing). Installation: Suitable for standard 86mm pattress box or European 60mm pattress box. The BHT-7000 range is developed to control electric underfloor, water heating, or water/gas boiler systems. Installer must be a trained, experienced service technician. A separate schedule may be set for weekdays and weekends.
- Page 2: About Wi-Fi Wi-Fi connection requires configuration through a smartphone or tablet. Step 1: Download the app by searching for Smartlife in the Apple Store or Google Play. Complete account registration and installation according to the app's guidance. Step 2: Connect the thermostat using Bluetooth network distribution or ordinary distribution network guidance. Simple exception handling includes checking connections if the power is on but without display. Temperature calibration may be necessary if the room temperature differs from the actual setting. Setting Wi-Fi to ON puts the thermostat in Wi-Fi pairing state. Your thermostat carries a 24-month warranty from the date of purchase.