Beca BHP-8000 C Room Thermostat User Guide
3.Disconnect the wires
Disconnect wires of W/W1, Y/Y1, R to thermostat from control board.
Heat pump (air or geothermal) with auxiliary heat
HVAC control board
Heat pump
W1 W2 Y1 Y2
Air handler
O/B
C
R
O/B W1 W2 Y1 Y2
G
R
C
W
C
G
Y
R
G
W
R
Y
To thermostat
W2
S
G
W1
O/B
RH
4.Connect the wiring module
Y1
Reconnect these wires to the 4-terminal side of the power module.
The wires and corresponding terminals are show below.
Y2
JAD
C
Rc
NTC
W→W;C→C;G→G;Y→Y;R→R
W
C
G
Y
R
Power module
For dual heat and cooling system,if applicable
Remove the jumper between Rh, Rc, or R terminals, adjust the
DIP switch on the back of the thermostat to 'Disconnect' if
you have connected both RC-wire and RH-wire to the
wallplate, otherwise switch it to the 'Connect' side.
W
C
S
R
G
Y
W
R
To thermostat
18
13