Beca BHP-8000 C Room Thermostat User Guide
09 Whether to turn on the
outdoor compressor at the
lowest temperature
3.Connect the wires to the base
Note: Connect the R or RC wire into the RC terminal, Connect other
wires to the corresponding terminals.
0: no 1: Yes , default 0
W2 W1 O/B RH
C
Rc
10 Compressor outdoor
minimum outdoor temperature
℃: 0-20,℉: 32-68
default ℃: 2,℉: 32
11 Turn on the maximum
temperature of the
auxiliary heat
0:no 1:Yes , default 0
12 Auxiliary heat on outdoor
maximum temperature
℃:0-18,℉:32-64
default ℃:18,℉: 64
S
G
Y1 Y2 JAD NTC
13 Whether the heat pump
compressor and auxiliary heat
are turned on at the same time
0:no 1:Yes , default 1
4.DIP Switch
If you have connected both the RC-wire and the RH-wire to the wall
plate, adjust the DIP on the back of the thermostat to Disconnect ,
otherwise switch it to Connect
℃:1.5-5 ,℉:3-9
default ℃: 1.5 ,℉: 3
14 Interval temperature
15 Cool& Heat set
16 ℉&℃ display
DIP Switch
0 to 3 , default 3
0: ℉ 1: ℃ , default 1
17 Reset to facture set
0:no 1:Yes , default 0
18 Filter replacement
countdown reminder
&
0 to 180 , default 180 days
0:no 1:Yes , default 0
19 Enable dual energy
0:Normal Code ,1: test Code
default 0
20 Production line test
21 Verison number
U1
9
22
| General | Details |
|---|---|
| Name | Beca BHP-8000 C Room Thermostat User Guide |
| Make | BECA |
| Language | English |
| Filetype | PDF (Download) |
| File size | 5.61 MB |

Beca BHT-9000 Thermostat User Guide

beca BAC-005 Series Thermostat User Guide

Beca BHT-6000 Series Round Thermostat User Guide

Beca BAC-1000 Series WiFi Thermostat User Guide

Beca BHT-002 Electric Heating Wifi Thermostat User Guide

Beca BHT-7000 Smart Knob Thermostat User Manual

Beca BHT-008 Heating Thermostat User Guide

Beca BAC-006 Zigbee Thermostat User Guide

Beca BHT-006 Series Thermostat User Manual

beca BAC-003 Series WiFi Thermostat Fan Coil User Guide