Home > American Standard > American Standard ACONT102 Non Programmable Thermostat User Guide

American Standard ACONT102 Non Programmable Thermostat User Guide

4.1 Location  
American Standard 102 Non-Programmable Thermostat  
2. Product Specifications  
SPECIFICATION DESCRIPTION  
Product Models  
ACONT102  
102  
Product  
Size  
3-7/8” x 5-1/2” x 1-3/16” (HxWxD)  
Heat / Cool  
Configurations  
Maximum Number of Stages  
Operating Temperature  
Shipping Temperature Range  
Input Power (DC)  
1H, 1C  
32°I to 105°I (0 to .41°C) 2 90% UH Non Condensing  
040°I to 150°I (040° to 66°C)  
Two 1.5V AAA Alkaline  
Input Power (AC)  
20 - 30 VAC, NEC Class ll, 50/60 HZ  
18 AWG  
Wire Usage  
System Modes  
Heating, Cooling, Off  
Fan Modes  
Auto, On  
Cooling Setpoint Temperature Range  
Heating Setpoint Temperature Range  
Temperature Display Range  
Minimum Cycle Off Time Delay  
Terminal Load  
45°I to 90°I, 1°I resolution  
45°I to 90°I, 1°I resolution  
4°I to 99°I, 1°I resolution  
Compressor: 5 minutes, Indoor Heat; none  
1.0A per terminal, 1.5A maximum all terminals combined  
32°I to .105°I (0° to .41°C)  
040°I to .150°I (040° to .65°C)  
Operating Ambient  
Shipping Temperature Range  
THERMOSTAT APPLICATION GUIDE  
Thermostat Applications  
Maximum Stages Heat/Cool  
1/1  
Gas, Oil, Hlectric, (mV and 24V), Heat Only, Cool Only or Heat2Cool Systems  
3. General Information  
4. Installation  
3.1 Overview  
The 102 is a non-programmable 1H/1C thermostat with a 2”  
The 102 is designed for installation in climate controlled living  
spaces. Place the unit in a central location with good circulation.  
digital display.  
For proper temperature sensing, avoid exposing the 102 to heat  
radiated from lamps, sun light, fireplaces or any other radiant heat  
source.  
3.2 Contents  
— 1-Thermostat  
— 2-Phillips slotted head mounting screws  
Avoid locations close to windows, behind doors or alcoves with  
poor air circulation, adjoining outside walls, or doors that lead to  
the outside.  
— 2-Nylon Drywall Anchors  
— 1-Installation Guide / User Guide  
Select a location that prevents the 102 from being directly exposed  
to air currents from supply registers or ceiling fans.  
Mount the Control on a section of interior wall that does not  
contain hot or cold water pipes or duct work.  
3
Pub. No. 11HD23D1-1B-EN 09/2020 Part No. 37-7771002  
GeneralDetails
NameAmerican Standard ACONT102 Non Programmable Thermostat User Guide
MakeAmerican Standard
LanguageEnglish
FiletypePDF (Download)
File size0.4 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
American Standard ACONT103 NP Non Programmable Heat Pump Thermostat Instruction Manual
American Standard ACONT103 NP Non Programmable Heat Pump Thermostat Instruction Manual

American Standard ACONT102 Non Programmable Thermostat User Guide