Home > American Standard > American Standard ACONT102 Non Programmable Thermostat User Guide
American Standard ACONT102 Non Programmable Thermostat User Guide
4.1 Location
American Standard 102 Non-Programmable Thermostat
2. Product Specifications
SPECIFICATION DESCRIPTION
Product Models
ACONT102
102
Product
Size
3-7/8” x 5-1/2” x 1-3/16” (HxWxD)
Heat / Cool
Configurations
Maximum Number of Stages
Operating Temperature
Shipping Temperature Range
Input Power (DC)
1H, 1C
32°I to 105°I (0 to .41°C) 2 90% UH Non Condensing
040°I to 150°I (040° to 66°C)
Two 1.5V AAA Alkaline
Input Power (AC)
20 - 30 VAC, NEC Class ll, 50/60 HZ
18 AWG
Wire Usage
System Modes
Heating, Cooling, Off
Fan Modes
Auto, On
Cooling Setpoint Temperature Range
Heating Setpoint Temperature Range
Temperature Display Range
Minimum Cycle Off Time Delay
Terminal Load
45°I to 90°I, 1°I resolution
45°I to 90°I, 1°I resolution
4°I to 99°I, 1°I resolution
Compressor: 5 minutes, Indoor Heat; none
1.0A per terminal, 1.5A maximum all terminals combined
32°I to .105°I (0° to .41°C)
040°I to .150°I (040° to .65°C)
Operating Ambient
Shipping Temperature Range
THERMOSTAT APPLICATION GUIDE
Thermostat Applications
Maximum Stages Heat/Cool
1/1
Gas, Oil, Hlectric, (mV and 24V), Heat Only, Cool Only or Heat2Cool Systems
3. General Information
4. Installation
3.1 Overview
The 102 is a non-programmable 1H/1C thermostat with a 2”
The 102 is designed for installation in climate controlled living
spaces. Place the unit in a central location with good circulation.
digital display.
For proper temperature sensing, avoid exposing the 102 to heat
radiated from lamps, sun light, fireplaces or any other radiant heat
source.
3.2 Contents
— 1-Thermostat
— 2-Phillips slotted head mounting screws
Avoid locations close to windows, behind doors or alcoves with
poor air circulation, adjoining outside walls, or doors that lead to
the outside.
— 2-Nylon Drywall Anchors
— 1-Installation Guide / User Guide
Select a location that prevents the 102 from being directly exposed
to air currents from supply registers or ceiling fans.
Mount the Control on a section of interior wall that does not
contain hot or cold water pipes or duct work.
3
Pub. No. 11HD23D1-1B-EN 09/2020 Part No. 37-7771002