5.2 OPERATING FEATURES  
Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the  
thermostat.  
SIMULTANEOUS HEATING/COOLING SETPOINT STORAGE You can enter both your heating and cooling setpoints at the  
same time. There is no need to re-enter the thermostat at the beginning of each season.  
TEMPERATURE SETTING — Press  
room temperature at the selected temperature.  
or  
until the display shows the temperature you want. The thermostat will keep the  
°F/°C CONVERTIBILITY — The factory default setting is Iahrenheit. Clipping W904 mumper on the circuit board will alter this  
feature to Celsius temperature setting. See diagram on page 11.  
LOW BATTERY INDICATOR — If the 2 “AAA” alkaline batteries are low and should be replaced, the display will be blank except  
for  
seconds, the display will be blank except for  
. When the batteries are low, pressing any button will cause the display to operate for ten seconds. After ten  
. After has been displayed for 4 weeks, the thermostat will  
raise the temperature 10° above your setpoint in COOL mode and drop the temperature 10° below your setpoint in HEAT mode.  
TEMPERATURE DISPLAY ADJUSTMENT Your new thermostat has been accurately set in our factory. However, if you wish,  
you may adjust your new thermostat temperature display to match your old thermostat. This can be accomplished (within a ±3°  
range) as follows:  
1. Press  
2. Press  
or  
or  
at the same time for two seconds with the SYSTEM switch in OFF position.  
to adjust the displayed temperature to your desired setting  
3. Move SYSTEM switch from OFF to exit the feature  
DISPLAY BACKLIGHT — The display backlight improves display contrast in low lighting conditions. Selecting backlight ON will  
turn the light on for a short period of time after any button is pressed. Selecting backlight OFF (default) will keep the light off. Turn  
the display backlight feature ON as follows:  
1. Press  
“-L” AND “FF” (off).  
2. Press or  
and  
at the same time for two seconds with the SYSTEM switch in HEAT position. The display will alternately show  
to change “FF” to “ON.”  
3. Move SYSTEM switch to OFF to exit the feature.  
10  
Pub. No. 11HD23D1-1B-EN 09/2020 Part No. 37-7771002  
GeneralDetails
NameAmerican Standard ACONT102 Non Programmable Thermostat User Guide
MakeAmerican Standard
LanguageEnglish
FiletypePDF (Download)
File size0.4 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
American Standard ACONT103 NP Non Programmable Heat Pump Thermostat Instruction Manual
American Standard ACONT103 NP Non Programmable Heat Pump Thermostat Instruction Manual

American Standard ACONT102 Non Programmable Thermostat User Guide