Home > American Standard > American Standard ACONT102 Non Programmable Thermostat User Guide
American Standard ACONT102 Non Programmable Thermostat User Guide
Installation and User Guide
Cooling with S9V2 Furnace
Thermostat
Indoor Unit
Outdoor Unit
Rc
R
Rh
O
B
Y
Y
B
Y1
G
G
W1
W
B
NOTES:
1) Wire third party condensate overflow
switches between Y of the thermostat
and Y1 of the airflow control board
2) X2 is required to energize aux heat
during defrost
Heat Cool Package with Variable Speed Blower
Thermostat
Rc
R
Rh
O
B
Y
Y1
G
G
W1
W
B
NOTES:
1) Wire third party condensate overflow
switches between Y of the thermostat
and Y1 of the airflow control board
2) X2 is required to energize aux heat
during defrost