Home > AIRZONE > AIRZONE Blueface Zero Thermostat User Manual

AIRZONE Blueface Zero Thermostat User Manual

ERRORS  
In the case of any of the following errors, please contact your installer:  
Communication errors  
EN  
1. Thermostat – Main control board / Zone Module  
2. Main control board – Zone Module  
8. Lite thermostat – Main control board  
9. Gateway – Airzone system  
10. BACnet gateway – Main control board  
11. Gateway – Indoor unit  
12. Webserver – Airzone system  
13. Control module of radiant elements – Main control board  
14. Expansion module – Main control board  
15. Consumption meter – Main control board  
17. Lutron gateway – Main control board  
18. Dehumidifier module – Main control board  
19. Alarm jumper error – Main control board  
C-02. Production control board – Main control board  
C-09. Air to water gateway – Production control board  
C-11. Air to water gateway – Air to water unit  
V01. AZX6CM1VALR Module – Main control board  
V02. AZX6CM1VALR Module – AZX6AC1VALR Head  
AC unit error. Anomaly in the AC unit  
Other errors  
3. Motorized element not connected to the actuator output  
4. Unusual behavior of the motorized element  
5. Open circuit in temperature probe  
6. Short circuit in temperature probe  
16. Measuring error in consumption meter  
F05-H. Heat battery temperature sensor is opened  
F05-C. Cold battery temperature sensor is opened  
F06-H. Heat battery temperature sensor is short circuited  
F06-C. Cold battery temperature sensor is short circuited  
F0506-HC. Heat or cold battery temperature sensor is opened or short circuited  
R05. Control module of radiant elements temperature sensor is opened  
R06. Control module of radiant elements temperature sensor is short circuited  
Airzone Lite errors  
In the case of Airzone Lite thermostats, if the On/Off icon  
blinks rapidly in red, it means  
communication with the main control board has been lost. On Acuazone (DI6) systems, this  
means loss of communication between the main control board and de zone module.  
Only in Acuazone (DI6) systems, if the On/Off icon  
communication with the zone module.  
blinks rapidly in purple means loss of  
16  
GeneralDetails
NameAIRZONE Blueface Zero Thermostat User Manual
MakeAIRZONE
LanguageEnglish
FiletypePDF (Download)
File size1.82 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
AIRZONE AZS62THINKRB, AZS62THINKRN Wireless Think Thermostat Instruction Manual
AIRZONE AZS62THINKRB, AZS62THINKRN Wireless Think Thermostat Instruction Manual
AIRZONE AZX6AIQSNSB-AZX6AC1VALR Think Wireless Monochrome Thermostat User Manual
AIRZONE AZX6AIQSNSB-AZX6AC1VALR Think Wireless Monochrome Thermostat User Manual
AIRZONE IBPRO6 FLEXA 3.0 Blueface Zero Wired Thermostat User Manual
AIRZONE IBPRO6 FLEXA 3.0 Blueface Zero Wired Thermostat User Manual

AIRZONE Blueface Zero Thermostat User Manual