- 1. Installation Manual (Installation, Operation And Maintenance → Invita Wifi Thermostat → Compatible With → Warning)
- 2. Important Safety Information (Installation → Equipment Connections → Wiring The Hvac Interface Module → Sequence Of Operation → Error Messages → Technical Data)
- 3. Important Safety Information (Notice)
- 4. Installation (Preparation → Tools Required → Materials Required → Notice → Thermostat Location)
- 5. Mount Invita Base To Wall (Attach The Thermostat To Back Plate → Mounting The Hvac Interface Module → Wiring The Invita Wifi Thermostat → Replace The Cover)
- 6. Equipment Connections (Conventional Systems → Heat Pump & Dual Fuel Systems → Accessory Options → Hrv/erv Ventilator → Optional Outdoor Sensor)
- 7. Wiring The Hvac Interface Module (Stage Heat And 1-stage Cooling With Fan → Jumpers: → Essential Settings:)
- 8. Up To 2-stage Furnace And 2-stage Air Conditioner (Up To 2-stage Hydronic Boiler And 2-stage Air Conditioner → Essential Settings: → Heating Type = Conventional → Equipment = 2 Heat/2 Cool → Radiant Floor Heating)
- 9. Up To 2-stage Heat Pump With Auxiliary Heat (Up To 2-stage Heat Pump With 2-stage Dual Fuel → Essential Settings)
- 10. Dehumidification Using A Dx Coil (Essential Settings: → Humidifier → Hrv/erv Ventilator → Outdoor Sensor)
- 11. Room Sensor (Floodsafe Water Detector Shutoff → Tekmar Humidity & Temperature Sensor 086 → Watts Floodsafe Water Detector Shutoff)
- 12. Home Screen (Go To Schedule → Current Temperature → Change Operating Mode → Go To Settings → Temperature Adjustment → Save To Schedule)
- 13. User Settings (Away → Schedule → Early Start)
- 14. Temperature Units (Energy Use → Daily Usage → Brightness Active → Brightness Inactive → Language → Screen Clean)
- 15. Time & Date (Options → Time Format → Time Source → Time Zone → Daylight Saving Time → Fan)
- 16. Wifi (Notice → Tutorial → Before First Using Wifi Features → Agree To Terms Of Use → Enter Password → Time Source)
- 17. Wifi And Connectivity (Troubleshooting → Check Router & Firewall → Network Troubleshooting → Create A Wifi Hotspot → Check Password)
- 18. Installer Settings (Setup → Toolbox → Access Level → Software Version → Load Defaults → Calibrate Touchscreen)
- 19. Setup (Floor Min - Wake → Floor Min - Leave → Floor Min - Return → Floor Min - Sleep → Floor Min - Away → Floor Max)
- 20. Setup - Sensors (Sensor 1 → Sensor 2 → Sensor 3 → Internal Room Sensor → Internal Humidity Sensor → Room Offset)
- 21. Setup - Alerts (Room Hot Warning → Room Cold Warning → Low Humidity Warning → High Humidity Warning → Auxiliary Heat Run Time Warning → Air Filter Change Warning)
- 22. Setup - Relays (1 Of 3) (Heating Type → Equipment → Radiant Floor Heating → Heat 1 Differential → Heat 2 Differential → Heat 3 Differential)
- 23. Setup - Relays (2 Of 3) (Setting → Range → Default → Heat 4 Delay → Cool 1 Differential → Cool 2 Differential)
- 24. Setup - Relays (3 Of 3) (Heat Pump Reversing Valve → Fan Relay → Fan With Hrv/erv → Humidifier Type → Window Protection → Dehumidifier Type)
- 25. Setup - Humidity (Humidity → Humidify → Dehumidify)
- 26. Setup - Hrv / Erv Ventilation (Ventilation Fan → Wake → Leave → Return → Sleep)
- 27. Sequence Of Operation (Heating And Cooling Operation → Conventional Systems → Equipment Setting → Heat Pump Systems)
- 28. Equipment Setting (Heating Differentials → Radiant Floor Heating → Room Sensor And Averaging)
- 29. Floor Sensor For Radiant Floor Heating (Cooling Differentials → Heat Pump Balance Point → Dual Fuel → Warm Weather Shut Down (wwsd) → Cold Weather Shut Down (cwsd))
- 30. Relative Humidity Operation
- 31. Hrv / Erv Ventilator Operation (Heat Pump Loop Valve Operation)
- 32. Error Messages (Description → Communication Error → Memory Error → Internal Room Sensor Fault → Internal Humidity Sensor Fault → Sensor 1 Fault → Sensor 2 Fault)
- 33. Description (Internet Unavailable → Water Leak Detector Warning → Room Hot Warning → Room Cold Warning → Low Humidity Warning → High Humidity Warning → Auxiliary Heat Run Time Warning)
- 34. Notes
- 35. Technical Data
- 36. Limited Warranty (Product Warranty Return Procedure)
×
WATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual
Setup - Humidity
Set the lowest relative
humidity level.
Humidity
Set the highest relative
humidity level.
Range is 10 to 80%
Default is 40%
Humidify To: 40%
Range is 20 to 90%
Default is 60%
Available when Accessory 1
or 2 operates a humidifier.
Dehumidify To: 60%
Available when Accessory 1
or 2 operates a dehumidifier.
25
| General | Details |
|---|---|
| Name | WATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual |
| Make | WATTS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.66 MB |

WATTS IOM-T-563 Tekmar WiFi Thermostat Installation Guide

WATTS BT-A03 RF Electronic Room Thermostat Installation Guide

WATTS TEK564 Invita WiFi Thermostat Instruction Manual

WATTS WTC-ES Contact Thermostat User Manual

WATTS 563 WiFi Thermostat User Manual

WATTS W561 WiFi Thermostat Instruction Manual

WATTS Tekmar Wi-Fi Thermostat Instruction Manual


EcoNet UETST800SYS Smart Thermostat User Guide

ICM CONTROLS SC2010 N-L Non Programmable Electronic Thermostat Instruction Manual

MI-HEAT MST1 Room Thermostat for Underfloor Heating User Manual

BEOK TDS72 Digital Screen Thermostat Instruction Manual

telkonet Aida Wireless Thermostat User Guide

Meross MTS200HK Smart Thermostat User Manual

TFC Group OP-WFSTAT Wi-Fi Thermostat User Guide

MAGNUM FIRST M9-TS1 24 Volt Intelligent Thermostat Owner’s Manual

ESi ESRTP6C, ESRTP6CW Centro Prog Room Thermostat User Guide

GENERAL SENNA 270S Smart Room Thermostat User Manual
Table of Contents
- 1. Installation Manual - Installation, Operation And Maintenanc... →
- 2. Important Safety Information - Installation →
- 3. Important Safety Information - Notice →
- 4. Installation - Preparation →
- 5. Mount Invita Base To Wall - Attach The Thermostat To Back Pl... →
- 6. Equipment Connections - Conventional Systems →
- 7. Wiring The Hvac Interface Module - Stage Heat And 1-stage Co... →
- 8. Up To 2-stage Furnace And 2-stage Air Conditioner - Up To 2-... →
- 9. Up To 2-stage Heat Pump With Auxiliary Heat - Up To 2-stage ... →
- 10. Dehumidification Using A Dx Coil - Essential Settings: →
- 11. Room Sensor - Floodsafe Water Detector Shutoff →
- 12. Home Screen - Go To Schedule →
- 13. User Settings - Away →
- 14. Temperature Units - Energy Use →
- 15. Time & Date - Options →
- 16. Wifi - Notice →
- 17. Wifi And Connectivity - Troubleshooting →
- 18. Installer Settings - Setup →
- 19. Setup - Floor Min - Wake →
- 20. Setup - Sensors - Sensor 1 →
- 21. Setup - Alerts - Room Hot Warning →
- 22. Setup - Relays (1 Of 3) - Heating Type →
- 23. Setup - Relays (2 Of 3) - Setting →
- 24. Setup - Relays (3 Of 3) - Heat Pump Reversing Valve →
- 25. Setup - Humidity - Humidity →
- 26. Setup - Hrv / Erv Ventilation - Ventilation Fan →
- 27. Sequence Of Operation - Heating And Cooling Operation →
- 28. Equipment Setting - Heating Differentials →
- 29. Floor Sensor For Radiant Floor Heating - Cooling Differentia... →
- 30. Relative Humidity Operation →
- 31. Hrv / Erv Ventilator Operation - Heat Pump Loop Valve Operat... →
- 32. Error Messages - Description →
- 33. Description - Internet Unavailable →
- 34. Notes →
- 35. Technical Data →
- 36. Limited Warranty - Product Warranty Return Procedure →