Home > WATTS > WATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual

WATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual

Setup - Relays (3 of 3)  
Setting  
Range  
Default  
HEAT PUMP REVERSING VALVE  
Select O for heat pumps designed for normally heating  
operation. Select B for heat pumps designed for normally  
cooling operation. This setting is only available for heat  
pump systems.  
O (Orange),  
B (Blue)  
O
G only,  
With Y  
FAN RELAY  
Select which relays require fan operation. Combinations  
with W1 are not available when Radiant Floor Heating is set  
to yes.  
With Y and W1,  
With Y and W2,  
With Y, W1 and W2  
G only  
FAN WITH HRV/ERV  
Off or On  
Off  
Select if the HVAC system fan should turn on together with  
the HRV or ERV ventilation fan.  
HUMIDIFIER TYPE  
Evaporative,  
Steam,  
Stand Alone  
Steam  
Select the type of humidifier. This setting is available when  
Accessory 1 or 2 is set to Humidifier.  
WINDOW PROTECTION  
Select if the relative humidity setpoint should automatically  
adjust with outdoor temperature to prevent frost on windows.  
Off or On  
Off  
This setting is available when Accessory 1 or 2 is set to  
Humidifier and the outdoor temperature is available (via  
sensor or internet).  
1 Pane  
2 Pane  
3 Pane  
WINDOW QUALITY  
The window quality determines the amount that the relative  
humidity setting is lowed during cold outdoor weather.  
2 Pane  
Choose the highest number of panes installed and best quality  
as a starting point. If window condensation appears, lower  
the setting until condensation stops forming. This setting is  
available when Accessory 1 or 2 is set to Humidifier and  
a wired outdoor sensor is installed.  
Average  
Poor  
Average  
Better  
DEHUMIDIFIER TYPE  
DX Coil,  
Stand Alone  
DX Coil  
Select the type of dehumidifier. This setting is available when  
Accessory 1 or 2 is set to Dehumidifier.  
HEAT-COOL TIME INTERLOCK  
When operating in Mode Auto, select the amount of time  
to wait between switching from heating to cooling and  
vice versa.  
10 to 180 minutes  
10 minutes  
WARM FLOOR DURING COOLING  
Select whether the floor should be heated when in cooling  
mode. This setting is only available when Radiant Floor  
Heating is set to yes.  
Yes or No  
No  
24  
GeneralDetails
NameWATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual
MakeWATTS
LanguageEnglish
FiletypePDF (Download)
File size0.66 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
WATTS IOM-T-563 Tekmar WiFi Thermostat Installation Guide
WATTS IOM-T-563 Tekmar WiFi Thermostat Installation Guide
WATTS BT-A03 RF Electronic Room Thermostat Installation Guide
WATTS BT-A03 RF Electronic Room Thermostat Installation Guide
WATTS TEK564 Invita WiFi Thermostat Instruction Manual
WATTS TEK564 Invita WiFi Thermostat Instruction Manual
WATTS WTC-ES Contact Thermostat User Manual
WATTS WTC-ES Contact Thermostat User Manual
WATTS 563 WiFi Thermostat User Manual
WATTS 563 WiFi Thermostat User Manual
WATTS W561 WiFi Thermostat Instruction Manual
WATTS W561 WiFi Thermostat Instruction Manual
WATTS Tekmar Wi-Fi Thermostat Instruction Manual
WATTS Tekmar Wi-Fi Thermostat Instruction Manual

WATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual