Code Parameter  
Factory  
setting  
Possible settings Comment  
01  
Sensor  
selection  
01  
01: Room sensor  
with floor tempe-  
rature limitation  
02: Room sensor  
03: Floor sensor  
The device offers control of the underfloor heating using a floor and a room temperature  
sensor. Optionally, either only one of the two sensors can be activated or both sensors can be  
selected at the same time. In this case, the room sensor controls the heating depending on  
the set maximum floor temperature (cf. code 04), which is used for limitation.  
02  
Room sensor  
calibration  
0 °C  
-5 °C ... +5 °C  
Allows you to calibrate the room sensor (integrated in the device) if the measured  
temperature differs from the actual room temperature. The usual self-heating of the device  
during its normal operation can affect the temperature measurement, as well as the  
positioning of the thermostat, e.g. near other heat sources, windows, doors.  
03  
04  
Floor sensor  
calibration  
Floor  
temperature  
limitation  
0 °C  
-5 °C ... +5 °C  
Allows you to calibrate the floor sensor if the measured temperature differs from the actual  
floor temperature.  
Allows you to set a maximum floor temperature as the upper temperature limit. This is  
particularly beneficial when, for example, laminate or click vinyl flooring is to be protected  
from excessively high temperatures.  
35 °C  
+5 °C ... +60 °C  
05  
06  
Week profile  
5-1-1  
5-1-1,  
7
According to the selected week profile, either all weekdays can be programmed individually  
or the working days are combined as one group.  
5-1-1 = Mon to Fri (as a group) - Sat - Sun / 7 = Mon - Tue - Wed - Thu - Fri - Sat - Sun (each  
weekday individually). Note: Relevant only for Program mode.  
Adaptive start  
(self-learning  
mode)  
Off (no)  
On (YES),  
Off (no)  
By continuously analyzing the previous heating characteristics, the thermostat automatically  
calculates the required turn-on time (preheating time) so that the set temperature can be  
achieved in time until the programmed time. If this function is OFF, the thermostat will turn  
on the heating exactly at the programmed time.  
Note: Relevant only for Program mode.  
07 *) Adaptive  
start time  
20 Min.  
0-40 Min.  
When the adaptive start function (cf. code 06) is activated for the first time, the heating is  
switched on earlier according to the preheating time selected under this item. Through the  
continuous analysis described under code 06, the preheating time for future heating periods  
will be adapted step by step to the requirements.  
(preheating  
time)  
08  
Open window  
detection  
Off (OFF)  
On (on),  
Off (OFF)  
The thermostat permanently monitors the room temperature. If it has dropped by more than  
5 degrees within 15 minutes, the thermostat assumes that window is open and turns off the  
heating for 30 minutes to save energy. Aſter this time, the heating control continues in the last  
active operating mode. If you change the operating mode during the 30 minutes, the open  
window detection will be cancelled immediately and the symbol on the display goes out.  
Note: Open window detection is active even if only the floor sensor (cf. code 01, setting 03)  
has been activated.  
09  
10  
Floor sensor  
type  
10 kOhm  
On (YES)  
3, 5, 6.8, 10, 12,  
15, 20, 22, 33,  
47 kOhm  
On (YES),  
Off (no)  
The device also supports other types of floor temperature sensors. This setting allows you to  
specify the type of floor sensor by selecting the appropriate nominal resistance.  
Anti-freezing  
mode  
Used to keep the temperature above the freeze point when a room is is not used for a longer  
period of time. This prevents e.g. pipes from freezing. The thermostat keeps the temperature  
above +5 °C. It means, at ≤ +5 °C the thermostat switches heating on, and switches off when  
+7 °C is reached. If you have activated this function by selecting On (YES), it will be active  
even if the thermostat is in stand-by.  
11 *) Holiday time  
1 day (01)  
1-99 days  
Setting of time of absence for the operation of the heating system in holiday mode.  
12  
Switching delay 1 °C  
0.5 °C, 1 °C, 2 °C,  
3 °C  
Switching delay means that the thermostat does not switch the heating on or off when exactly  
the set target temperature is reached, but earlier or later by the selected switching tolerance  
value.  
Example: Set temperature 26 °C, switching delay 1 °C, the thermostat switches the heating on  
at ≤ 25 °C and off at ≥ 27 °C.  
The lower the set value for the switching delay, the more circuits of the controller.  
The larger the set value, the less accurate the temperature control.  
13 *) Display  
accuracy  
0.5 °C  
0.5 °C, 0.1 °C  
Setting at which degree of accuracy the temperature is to be shown on the display. Either 0.1  
°C steps (e.g. 23.1 °C, 23.2 °C) or 0.5 °C steps (e.g. 23.0 °C, 23.5 °C).  
14 *) Temperature  
0.5 °C  
0.1 °C, 0.5 °C, 1 °C  
Setting in which °C steps the set temperature can be adjusted.  
input steps  
15  
Reset  
No (no)  
Yes (YES),  
No (no)  
Allows to reset the device to factory settings.  
Note: If “YES” is selected, long tap o to confirm until the main screen appears.  
The device is now reset.  
16 *) Display indica-  
tion when device  
is switched off  
02  
01: Displays OFFAllows you to select the information to be shown on the display when the device is switched  
02: Temperature  
is displayed  
off.  
17  
Temperature  
°C  
1
°C, °F  
Selection of the temperature unit, Celsius oder Fahrenheit.  
unit  
18 *) Device status  
at restart (aſter  
the device was  
disconnected  
from the power  
supply)  
1: Return to  
previous  
operating state  
2: Device OFF  
3: Device ON  
Setting to which status the device is to be set aſter the power supply has been restored  
(e.g. if a power failure occured).  
1: The device returns to the previous operating state (from before the power interruption). If  
the thermostat was switched off, it remains switched off. If the device was turned on, it returns  
to the previous active operating mode.  
2: The device is or remains switched off.  
3: The device is switched on and continues to operate in the previous active operating mode.  
14  
GeneralDetails
Nametuya Mi-750 WiFi Smart Thermostat Instruction Manual
MakeTuya
LanguageEnglish
FiletypePDF (Download)
File size2.71 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
tuya M3 Series Thermostat User Guide
tuya M3 Series Thermostat User Guide
tuya MTS700N Wireless Thermostat User Manual
tuya MTS700N Wireless Thermostat User Manual
tuya BHT-005 Wifi Heating Thermostat User Manual
tuya BHT-005 Wifi Heating Thermostat User Manual
tuya TRV603 Smart WiFi Radiator Thermostat Instruction Manual
tuya TRV603 Smart WiFi Radiator Thermostat Instruction Manual

tuya Mi-750 WiFi Smart Thermostat Instruction Manual