Home > Tuya > tuya Mi-750 WiFi Smart Thermostat Instruction Manual

tuya Mi-750 WiFi Smart Thermostat Instruction Manual

Connect all required wiring to the thermostat using its terminals with  
screw fastening.  
Installation  
Floor temperature sensor installation  
The floor temperature sensor cable  
The floor temperature sensor must be connected to the two terminals  
marked with NTC (polarity does not matter).  
has to be placed into a separate  
conduit according to EN 61386-1.  
It should be placed at heating level  
directly underneath the heating mat  
by chiselling out a channel in the  
subfloor. The sensor should be  
centrally positioned between two  
heating conductors, which is in  
the middle of a cable loop. Route the  
Important!  
If the installation distance is shorter than the sensor installation wire  
(standard 3m), the sensor cable must be shortened accordingly.  
The supply voltage (230 V AC) is applied to terminal N and L, with the  
phase wire (detected by voltmeter) – to terminal L, and the neutral  
wire – to terminal N.  
The heating element installation wires are to be connected to termi-  
nals N LOAD and L LOAD; the screening braid output (yellow-green wire)  
must be connected to the protective earthing (PE) line via an external  
terminal contact (not included in the scope of delivery).  
heating mat cold lead through the second corrugated tube. Do not cross  
the cold lead over or place it closer than about 2 cm to the mat heating  
wires. Thermostat installation requires a standard plastic wall mounting  
box with 230 V AC mains connection cable from the local wiring at the  
intended location. A fault-current circuit breaker (30 mA) has to be used.  
Double-check that the floor sensor is positioned in a corrugated tube  
(Ø16mm) and can be easily removed from; check this during installa-  
tion of the tube and again before installation of the screed and floor  
covering respectively!  
L
O
A
D
L
O
A
D
NTC  
N
N
L
L
t
230 VAC  
Max. Load 16 A  
Connect the thermostat  
Important!  
Important!  
We recommend to use the services of qualified specialists when installing  
the thermostat and heating system. The electrical connection and  
connection to the power supply must be performed by a professional  
electrician in compliance with the applicable national laws, rules and  
regulations. The installation instructions and wiring diagram do not  
replace the professional skills of the device installer. Disconnect your  
local wiring from the mains before connecting the thermostat or  
disconnecting the device to check or replace it.  
In order to keep the thermal impact on the relevant device components  
low in the event of improper use under continuous load and to achieve  
maximum service life, it is recommended to switch (connect) a maximum  
load current of 13 A (2990 W).  
Mounting the thermostat  
1. Remove the front cover (part with display). Carefully press the latch  
on the upper side of the front cover using a thin slot screwdriver and  
gently pull the front cover off in your direction.  
86.0  
24.5  
9.0 11.3  
65.5  
2. Make the electrical connection.  
3. Insert the rear cover of the device into the wall mounting box and  
fasten with two screws, leſt and right at the same height.  
4. Insert the display into the frame and align the connector contacts on  
the rear with the connector receptacle on the rear cover.  
5. Carefully press the front cover with the frame against the rear cover  
(inserted in the flush-mounted box before) until the latch lock in  
place. Make sure that the front cover tightly adjoins the rear part of  
the thermostat.  
Important!  
Avoid damaging or bending the contacts of the connector during  
installation.  
2
1
60.0  
Front cover  
Rear cover  
3
51.0  
Install the mounting box with suitable screw spacing of 60 mm and the  
intermediate junction box if necessary (e.g. if two or more heating mats  
are to be connected and controlled with one thermostat). Lead power  
supply cable, installation wires of the floor heating, and temperature  
sensor installation wire to the box. Energize the supply cable and find  
the phase wire and the neutral wire using voltmeter; mark these wires.  
Aſterwards, de-energize the power supply cable.  
Display  
Receptacle of  
the connector  
11  
GeneralDetails
Nametuya Mi-750 WiFi Smart Thermostat Instruction Manual
MakeTuya
LanguageEnglish
FiletypePDF (Download)
File size2.71 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
tuya M3 Series Thermostat User Guide
tuya M3 Series Thermostat User Guide
tuya MTS700N Wireless Thermostat User Manual
tuya MTS700N Wireless Thermostat User Manual
tuya BHT-005 Wifi Heating Thermostat User Manual
tuya BHT-005 Wifi Heating Thermostat User Manual
tuya TRV603 Smart WiFi Radiator Thermostat Instruction Manual
tuya TRV603 Smart WiFi Radiator Thermostat Instruction Manual

tuya Mi-750 WiFi Smart Thermostat Instruction Manual