Home > Honeywell > T10 Pro Smart Thermostat with Redlink Room Sensor

T10 Pro Smart Thermostat with Redlink Room Sensor

Troubleshooting  
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and  
easily.  
Display is blank  
Check circuit breaker and reset if necessary.  
Make sure power switch for heating and cooling is on.  
Make sure furnace door is closed securely.  
Make sure the C-wire is connected.  
Make sure R/Rc slider tab is set correctly (see wiring diagrams).  
Heating or cooling system does not respond  
Press Menu > System Mode > Heat > Done to set the system to Heat mode. Make sure the desired temperature is higher  
than the indoor temperature.  
Press Menu > System Mode > Cool > Done to set the system to Cool mode. Make sure the desired temperature is lower than  
the indoor temperature.  
Check circuit breaker and reset if necessary.  
Make sure power switch for heating and cooling system is on.  
Make sure furnace door is closed securely.  
Wait 5 minutes for the system to respond.  
Temperature settings do not change  
Make sure desired temperature is within acceptable ranges:  
Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)  
Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)  
Aux heat runs in cooling  
For heat pump systems, verify there is not a wire attached to W on the UWP.  
Cool runs with a call for heat  
For heat pump systems, verify there is not a wire attached to W on the UWP.  
Sensor will not connect  
Press and hold Connect on the wireless sensor for 15 seconds. The LED will turn Amber. Return to the thermotat menu and  
press Menu > Devices and Sensors. Follow the on-screen instructions to add the sensor.  
31  
33-00428–03  
Specifications  
Temperature Ranges  
Regulatory Information  
FCC REGULATIONS  
§ 15.19 (a)(3)  
This device complies with part 15 of the FCC Rules. Operation  
is subject to the following two conditions:  
1. This device may not cause harmful interference, and  
2. This device must accept any interference received,  
including interference that may cause undesired operation.  
Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)  
Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)  
Operating Ambient Temperature  
32 °F to 120 °F (0 °C to 48.9 °C)  
Shipping Temperature  
-20 °F to 120 °F (-28.9 °C to 48.9 °C)  
Operating Relative Humidity  
5% to 90% (non-condensing)  
Humidity setting range  
10% to 60% RH.  
Dehumidity setting range  
IC REGULATIONS  
RSS-GEN  
This device complies with Industry Canada’s license-exempt  
RSSs.  
Operation is subject to the following two conditions:  
1. This device may not cause interference; and  
2. This device must accept any interference, including  
interference that may cause undesired operation of the  
device.  
Originally 40% to 80% RH. Lowered to 25% RH min on  
Oct 3 2019. Also updated via app.  
FCC Warning (Part 15.21) (USA only)  
Physical Dimensions in inches (mm) (H x W x D)  
Changes or modifications not expressly approved by the party  
responsible for compliance could void the user’s authority to  
operate the equipment.  
T10 PRO Wi-Fi Thermostat:  
4.9” x 3.7” x 0.93” (125.4 x 94.1 x 23.68)  
UWP Mounting System (included):  
2-9/32” x 2-13/64” x 2-43/64” (58 x 56 x 10)  
This product should not be disposed of with other household  
waste. Check for the nearest authorized collection centers  
or authorized recyclers. The correct disposal of end-of-life  
equipment will help prevent potential negative consequences  
for the environment and human health.  
Wireless temperature, humidity, and motion sensor:  
2.6” x 2.6” x .78” (66.25 x 66.25 x 19.7)  
Cover Plate (included with THX321WFS2001W):  
5 11/64” x 5 1/2” x 11/16” (131.4 x 139.7 x 17.5)  
Cover Plate (included with THX321WF2003W):  
6 7/64” x 6 7/64” x 9/32” (155 x 155 x 7)  
Electrical Ratings  
Terminal  
Voltage  
(50/60Hz)  
Running  
Current  
W Heating  
20-30 Vac  
20-30 Vac  
20-30 Vac  
20-30 Vac  
20-30 Vac  
20-30 Vac  
20-30 Vac  
20-30 Vac  
0.02-1.0 A  
0.02-1.0 A  
0.02-0.5 A  
0.02-1.0 A  
0.02-1.0 A  
0.02-0.5 A  
0.02-0.5 A  
0.02-0.5 A  
W2 (Aux) Heating  
E Emergency Heat  
Y Compressor Stage 1  
Y2 Compressor Stage 2  
G Fan  
O/B Changeover  
L/A Input  
U
20-30 Vac  
0.02-0.5 A  
Power Consumption  
3 VA  
33-00428–03  
32  
GeneralDetails
NameT10 Pro Smart Thermostat with Redlink Room Sensor
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.57 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell Smart Color Touchscreen Programmable Thermostat RTH9590 User Manual
Honeywell Smart Color Touchscreen Programmable Thermostat RTH9590 User Manual

T10 Pro Smart Thermostat with Redlink Room Sensor