Floor Sensor (NTC 10K by default)  
High Level, Mid Level, Low Level.  
If external sensor is broken, the user can buy NTC sensor by themselves, the available sensor types are as  
follows:  
This brightness can also be configured through the proprietary attribute OperateDisplayLcdBrightness  
(0x1000) of Thermostat Cluster (0x0201).  
NTC 100K/25 (3m,NTC,R25=100KΩ±1%@25, B25/50=3950K±1%)  
NTC 50K/25 (3m,NTC,R25=50KΩ±1%@25, B25/50=3950K±1%)  
NTC 15K/25 (3m,NTC,R25=15KΩ±1%@25, B25/50=3950K±1%)  
NTC 10K/25 (3m,NTC,R25=10KΩ±1%@25℃, B25/50=3950K±1%)  
Display Auto Off (60S by factory setting)  
By factory setting, once the device goes to standby interface, if there is no operation within 1 minute, the  
display will go off automatically.  
NTC 12K/25 (3m,NTC,R25=12KΩ±1%@25℃, B25/50=3950K±1%)  
This sensor type can also be configured through the proprietary attribute FloorSensorType (0x1002) of  
Thermostat Cluster (0x0201).  
Child Lock  
On the Home Interface, press and hold both  
and  
buttons for over 10S, the Child Lock can be enabled  
will appear at the upper right corner, otherwise the  
or disabled, when the Child Lock is enabled, the icon  
icon will not appear.  
Key vibration level (OFF by default)  
Internal Over Heat Protection  
Set the level of vibration sensor under the buttons or buzzer level.  
OFF: vibration or buzzer off  
To ensure the safety of the device, if the internal temperature of the device (not displayed on the interface)  
Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level  
This level can also be configured through the proprietary attribute ButtonVibrationLevel (0x1001) of  
Thermostat Cluster (0x0201).  
is over a certain value during heating process, the device will execute a short temporary action to turn off the  
relay, and the icon  
will appear on the interface , after the temperature decreases to a certain value, the  
device will recover to work.  
Control type (Room sensor by default)  
4.10 Zigbee Configuration Introduction  
Control type means which temperature sensor the device refers to when it adjust temperature.  
Room sensor: adjust temperature refers to room temperature (factory default type)  
Floor sensor: adjust temperature refers to floor temperature  
Select  
Network Set on Home Interface to enter into Zigbee network management interface as follow:  
Room+Floor sensor: adjust temperature refers to both room temperature and floor temperature. Turn on heat  
valve under other circumstances. This mode is to prevent the device from continuous heating that caused by  
malfunction of either sensor. When the floor sensor temperature is >= the set temperature minus 1 or when the  
room sensor is >= the set temperature, either of the conditions is achieved, the controller will stop heat,  
otherwise the controller will heat.  
This control type can also be configured through the proprietary attribute ControlType (0x1003) of Thermostat  
Cluster (0x0201).  
Adding to a Zigbee Network  
Operate your Zigbee gateway to add device, select “Add”, then short press button  
, the device will search  
F
network and try to join, “Status” will show “Inclusion...”. If there is no response from a gateway, or adding failed,  
“Status” will show “Fail”. If added successfully, “Status” will show “Inclusion OK” and device ID.  
Temp compensation (0 by default)  
The displayed temperature may has big tolerance caused by the sensor or other factors, so it is necessary to do  
temp compensation to room sensor and floor sensor.  
Removing from a Zigbee Network  
Compensation range is -5 ~ +5, stepping is 0.5.  
Operate your Zigbee gateway to remove device, Select “Remove”, then short press button  
, the device will  
F
This value can also be configured through the attribute LocalTemperatureCalibration (0x0010) of Thermostat  
Cluster (0x0201), and through the proprietary attribute FloorSensorCalibration (0x1005) of Thermostat Cluster  
(0x0201).  
send out removing request, “Status” will show “Exclusion...”. If there is no response from a gateway, or  
removing failed, “Status” will show “Fail”. If removed successfully, “Status” will show “Exclusion OK” and device  
ID will be showed as 0.  
The device will be removed from the network and all parameters will be restored to factory default setting, all  
bindings will be cleared.  
RePower status(last status by default)  
Device state after reset power of the device.  
Factory Reset (Reset)  
If set as “last status”, device will go to the status before power failure after power on again.  
If set as “default”, device will go to default mode after power on again.  
This status can also be configured through the proprietary attribute PowerUpStatus (0x1004) of Thermostat  
Cluster (0x0201).  
Factory resetting will remove the device from Zigbee network and all parameters will be restored to factory  
default setting, all bindings will be cleared.  
Select “Reset”, then short press button  
F
exclusion failed, “Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”.  
, the device will start reset, “Status” will show “Reset...”. If  
Display Temp type (Home Temp by default)  
This parameter defines which sensor temperature will be displayed on Home page.  
Floor Temp: floor temperature (external sensor).  
Configure Device Operation Mode through Zigbee  
Since Zigbee does not have away mode, the attribute Occupancy (occupied or unoccupied) of Thermostat  
(0x0201) and attribute Occupancy of received OccupancySensing (0x0406) are required to judge whether  
it is away mode.  
Home Temp: indoor air temperature.  
This status can also be configured through the proprietary attribute TemperatureDisplay (0x1008) of  
Thermostat Cluster (0x0201).  
1) if the device receives other devices’ or the gateway’s report: the Bit 0 of the value of attribute  
Occupancy (0x0000) of OccupancySensing Cluster (0x0406) is 1, which means occupied, then the  
operation mode of the thermostat, the attribute SystemMode(0x001c)=0x04(heat) of Thermostat (0x0201),  
Operate Brightness (Mid Level by default)  
The OLED display brightness when operate the device.  