Home > SIEMENS > SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual

SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual

Technical Instructions  
Document Number 155-067P25  
February 11, 2022  
TH 192 DN Day-Night and DNV Day-Night-Vent Room Thermostat  
1. Remove the thermostat chassis from the wall. The terminal does not have a ball check  
valve.  
Chassis Tube  
Connector and  
Restrictor Plate  
Replacement  
NOTE: You must close off the supply air. For example, use a connector with the supply air  
terminal plugged.  
2. Remove the two Phillips head screws from the connector on back of the thermostat  
chassis. Pull the connector out of the recess. If necessary, pry the connector loose with  
a screwdriver, but be careful not to damage the restrictor plate and gasket.  
3. Remove the gasket from under the connector. Remove the restrictor. Remove the  
second gasket from under the restrictor.  
4. Use Restrictor Replacement Kit 192-321 to replace the gasket, restrictor, and second  
gasket.  
NOTE: The restrictor plate is keyed to ensure proper orientation during installation.  
5. Remove the filters from the existing connector and insert in the new connector. Or, if  
filters are dirty, use Restrictor Replacement Kit 192-321 to replace filters.  
6. Use Chassis Tube Connector Replacement Kit 192-525 to replace the connector and  
mounting screws.  
Service Parts  
The following chart lists accessory parts and tools available for thermostat service:  
Description  
Part Number  
141-0573  
Dial thermometer (-40 to 140F, -40 to 60C) with pocket case  
Basic pneumatic calibration kit with thermometer, gauge, squeeze  
bulb, fittings, and case  
832-177  
Test head kit  
832-179  
832-178  
Calibration tools  
Test probe to check pressure with cover on  
Needle probe with 1-1/2” diameter gauge 0 to 30 psig (0 to  
200 kPa) and calibration/cover wrench  
192-633  
Needle probe, no gauge (package of five)  
192-759  
1-1/2” diameter compound gauge, 0 to 30 psig/0 to 200 kPa,  
142-0473  
back connected 1/8” NPT male  
1-1/2” diameter compound gauge, 0 to 30 psig/0 to 200 kPa,  
bottom connected 1/8” NPT male.  
Replacement for use with 192-633  
142-0476  
Chassis tube connector replacement kit with mounting screws  
(material for 10 thermostats included)  
192-525  
192-321  
Restrictor plate replacement kit with filters and gasket  
(material for 10 thermostats included)  
Page 12  
Siemens Industry, Inc.  
GeneralDetails
NameSIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual
MakeSIEMENS
LanguageEnglish
FiletypePDF (Download)
File size0.16 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual
SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual
SIEMENS M3182 Room Thermostat Instruction Manual
SIEMENS M3182 Room Thermostat Instruction Manual
SIEMENS RDS120-B Smart Thermostat Instructions
SIEMENS RDS120-B Smart Thermostat Instructions
SIEMENS RDG400 Room Thermostat Instruction Manual
SIEMENS RDG400 Room Thermostat Instruction Manual
SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual
SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual
SIEMENS RDH100RF/SET Room Thermostat Instruction Manual
SIEMENS RDH100RF/SET Room Thermostat Instruction Manual
SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide
SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide
SIEMENS RS485 Flush Mounted Room Thermostat User Manual
SIEMENS RS485 Flush Mounted Room Thermostat User Manual
SIEMENS RDG260KN Room Thermostat Instruction Manual
SIEMENS RDG260KN Room Thermostat Instruction Manual
SIEMENS RDF660MB Flush Mount Room Thermostat Instruction Manual
SIEMENS RDF660MB Flush Mount Room Thermostat Instruction Manual

SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual