SETTING THE OPERATING SCHEDULES  
SETTING THE OPERATING SCHEDULES  
LCD SYMBOLS  
INSTALLATION  
For 7 day programmable mode  
For 5+2 day programmable modedefault)  
Carefully separate the front half of the thermostat from  
the back plate by placing a small flat head terminal driver  
into the slots on the bottom face of the thermostat.  
Carefully unplug the cable connector which is plugged  
into the front half of the thermostat.  
Place the thermostat front half somewhere safe.  
Follow the Wiring Diagram to connect the floor heating  
cold leads, floor temperature sensor and electrical  
supply to the appropriate terminals.  
power on / off  
Default Settings  
Default Settings  
mode button / menu button  
program button  
MONDAY - FRIDAY  
SATURDAY - SUNDAY  
MONDAY - SUNDAY  
SETPOINT  
TIME  
ZONE 1 ZONE 2  
SETPOINT  
TIME  
ZONE 1 ZONE 2  
SETPOINT  
PROGRAM  
PROGRAM  
TIME  
ZONE 1 ZONE 2  
22O  
22O  
C
ON)  
22O  
ON)  
0700 22OC  
C
22OC  
ON)  
22O  
0700  
C
0700  
C
0930 16OC  
1630 22OC  
2230 16OC  
0930 16OC  
16OC  
OFF)  
22OC  
ON)  
16OC  
OFF)  
16OC  
OFF)  
0930 16OC  
1630 22OC  
2230 16OC  
confirm the settings  
increase  
1630 22O  
22OC  
ON)  
22O  
C
C
ON)  
2230 16OC  
16OC  
OFF)  
16OC  
16OC  
OFF)  
Screw the thermostat back plate onto the flush box.  
Re-connect the thermostat cable and clip the two halves  
back together.  
OFF)  
Changing programs for Monday- Friday  
Press  
Use  
, the day display will start flashing.  
decrease  
Press  
Use  
, the time for  
(Program 1) will flash.  
to select the day.  
DIMENSIONS  
60mm  
to adjust the time for Program 1.  
, the setpoint for Program 1 will flash.  
to adjust the setpoint for Program 1.  
auto mode  
Press and hold  
for about 5 seconds to  
Press  
Use  
80mm  
45mm  
select all 7 days of the week, and to cancel press and  
manual mode  
and hold  
Press  
Use  
for about 5 seconds again.  
, the time for (Program 1) will flash.  
Press  
Use  
, the time for  
(Program 2) will flash.  
flashing  
temporary override  
key lock symbol  
the heating is turned on  
the program numbers  
set temperature  
to adjust the time for Program 2.  
, the setpoint for Program 2 will flash.  
to adjust the setpoint for Program 2.  
to adjust the time for Program 1.  
, the setpoint for Program 1 will flash.  
to adjust the setpoint for Program 1.  
Press  
Use  
Press  
Use  
Repeat above steps for Program 3 and Program 4  
.
Press  
Use  
, the time for  
(Program 2) will flash.  
to adjust the time for Program 2.  
, the setpoint for Program 2 will flash.  
to adjust the setpoint for Program 2.  
Changing programs for Saturday- Sunday  
When Monday-Friday programs have been set, continue  
Press  
Use  
WIRING DIAGRAM  
to press  
Use  
, the time for  
(Program 1) will flash.  
sensor not installed or error  
to adjust the time for Program 1  
.
7
6
5
4
3
2
1
Repeat above steps for program 3 and Program 4  
.
Press  
Use  
, the setpoint for Program 1 will flash.  
to adjust the setpoint for Program 1.  
Note:  
For Saturday-Sunday, if you want to clear the time  
period of Program 2 and Program 3, press  
Press  
Use  
, the time for  
(Program 2) will flash.  
TECHNICAL INFORMATION  
8A  
to adjust the time for Program 2.  
during programing. Press  
again to cancel.  
SPECIFICATIONS  
Press  
Use  
, the setpoint for Program 2 will flash.  
to adjust the setpoint for Program 2.  
Sensor 1  
8A  
SUPPLY VOLTAGE  
SWITCHING CAPABILITY  
TEMP RANGE(A)  
230-240 VAC  
8A max for each zone  
5°C~35°C  
Repeat above steps for Program 3 and Program 4  
.
N
L
FLOOR SENSOR  
10 Kohm.  
Note:  
For Saturday-Sunday, if you want to clear the time  
period of Program 2 and Program 3, Press  
resistance default to 25°C  
IP RATING  
ORIENTATION  
Sensor 2  
AC 230V  
30  
VERTICAL  
Note: Heater 1 refers to heating element in zone 1  
Heater 2 refers to heating element in zone 2  
Sensor 1 refers to sensor installed for zone 1  
Sensor 2 refers to sensor installed for zone 2  
during programing. Press  
again to cancel.  
GeneralDetails
NameRTH21 Programmable Thermostat Coldbuster Dual Instruction Manual
MakeCOLDBUSTER
LanguageEnglish
FiletypePDF (Download)
File size0.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COLDBUSTER MWD5 Programmable Thermostat User Manual
COLDBUSTER MWD5 Programmable Thermostat User Manual
COLDBUSTER CB Dual Thermostat User Manual
COLDBUSTER CB Dual Thermostat User Manual
COLDBUSTER MCD5 Programmable Thermostat User Manual
COLDBUSTER MCD5 Programmable Thermostat User Manual

RTH21 Programmable Thermostat Coldbuster Dual Instruction Manual