Home > QuietWarmth > QUIETWarmth Type UCG Thermostat User Manual
QUIETWarmth Type UCG Thermostat User Manual
Type UCG/UDG
English
6 Press the Up or Down buttons to select one of the four types of
control:
ROOM: The built-in room sensor is used. Only room temperature is
controlled.
FLOOR
Room/floor/regulator
On/Off
TIME
FLOOR: A floor sensor is used. Only floor temperature is controlled.
REGULATOR: The thermostat functions as a simple regulator and no
sensors are used.
DAY
CHILDLOCK
C°/F°
SETTINGS
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
ROOM LIMIT: The thermostat controls room temperature while using
the external temperature sensor as a limit sensor. If you choose this
option, you must set a maximum and minimum temperature for the
limit sensor, so that the thermostat will switch the heating off or on
if the temperature on the floor reaches the maximum or minimum
temperature respectively. This can, for instance, be used to avoid
excessively high temperatures on wooden flooring (maximum limit) or
excessively cold temperatures on tiled/stone flooring (minimum limit).
7 Press the OK button.
On/Off
8 If FLOOR or ROOM LIMIT is chosen, maximum and minimum floor
temperatures can now be set. Press the Up or Down buttons to set
the High temperature. Press OK and set the Low temperature. Press
the OK button.
Factory Reset
I want to return to the factory settings.
9 Follow the Exit Menu procedure to exit the menu.
To do so, you must:
1 With Active Display (backlight on) press OK to activate the menu.
2 Press the Up or Down buttons until the SETTINGS option flashes.
3 Press the OK button.
Please note: Usually, the electrician who installed the thermostat will have
selected the correct type of temperature control for your application.
4 Press the Up or Down buttons until the FACTORY RESET option
flashes.
5 Press the OK button. A submenu will appears.
6 Press the Up or Down buttons until the RESET option flashes.
7 Press the OK button.
ROOM
FLOOR
REGULATOR
ROOM LIMIT
8 Follow the Exit Menu procedure to exit the menu.
TIME
DAY
TIME
CHILDLOCK
DAY
SETTINGS
C°/F°
CHILDLOCK
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
SETTINGS
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
FACTORY RESET
EXIT
RESET
EXIT
Error Messages
E0 = Internal failure. Replace thermostat.
E1 = Internal sensor defective or short-circuited. Replace thermostat.
E2 = External sensor defective or short-circuited. Check external sensor.
Display
I want to choose the information to be shown on the thermostat
display.
Factory Settings for Automatic 5:2 Program
To do so, you must:
1 With Active Display (backlight on) press OK to activate the menu.
2 Press the Up or Down buttons until the SETTINGS option flashes.
3 Press the OK button.
4 Press the Up or Down buttons until the DISPLAY option flashes.
5 Press the OK button.
6 Press the Up or Down buttons to select whether or you wish to:
- display the Clock or not (On/Off),
- display the Set temperature or not (On/Off).
- You can also decide whether the temperature displayed is the Room
temperature, the Floor temperature (if a floor sensor is used) or the
Regulator temperature.
Days 1-5 (Monday - Friday)
Event
Morning
Out
Time
Temperature
77 °F / 25 °C
68 °F / 20 °C
77 °F / 25 °C
68 °F / 20 °C
6:00 a.m. - 8:00 a.m.
8:00 a.m. - 4:00 p.m.
4:00 p.m. - 10:00 p.m.
10:00 p.m. - 6:00 a.m.
Days 6-7 (Saturday - Sunday)
Time
Home
Night
7 Press the OK button to confirm the settings as you work your way
through the various options in the DISPLAY submenu.
8 Follow the Exit Menu procedure to exit the menu.
Event
Day
Temperature
77 °F / 25 °C
68 °F / 20 °C
8:00 a.m. - 11:00 p.m.
11:00 p.m. - 08:00 a.m.
Factory settings:
TIME: ON; SET TEMP.: ON; TEMP.: FLOOR
Night
© 2012 OJ Electronics A/S