Home > PRAXISDIENST > PRAXISDIENST DZ 003 Dry Block Thermostat User Manual

PRAXISDIENST DZ 003 Dry Block Thermostat User Manual

5
5.  
General information about the Dry Block Thermostat  
In order to carry out kinetics tests more efficiently in the laboratory, it is  
necessary to preheat the samples before measurement. In addition, the reagents  
must also be kept at incubation temperature during a series of measurements.  
For this purpose, a small and handy dry block thermostat was developed as a  
stand-alone system in addition to the Diaglobal Photometers.  
The features in detail are:  
Temperature unit of 37 °C with an accuracy of 0.2 °C  
12 positions for round cuvettes  
Indication of temperature control by LED  
Heating up in 5 minutes per cuvette filled with 1000 L  
Power supply:  
AC-Adapter:  
12 VDC / 15 VA  
110 - 240 VAC 50/60 Hz  
6.  
Delivery and Installation  
Delivery  
After carefully unpacking the device, check whether it is in perfect condition.  
Also, check if it is complete according to the delivery note. The box contains the  
following items:  
Dry Block Thermostat and AC-Adapter  
The packaging materials must be stored carefully in case an item needs to  
be returned. Notify your dealer immediately if any defects are found.  
Installation  
Connect the AC-Adapter to the mains.  
The operating voltage range is between 110 VAC and 240 VAC at 50/60 Hz.  
Plug the connector into the socket on the backside of the Dry Block Thermostat.  
The Dry Block Thermostat DZ 003 is switched on with the red switch on the front  
of the device.  
After a few seconds, the green LED flashes. The red LED shows a continuous  
light.  
Edition 2021-01  
GeneralDetails
NamePRAXISDIENST DZ 003 Dry Block Thermostat User Manual
MakePRAXISDIENST
LanguageEnglish
FiletypePDF (Download)
File size0.11 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

PRAXISDIENST DZ 003 Dry Block Thermostat User Manual