Safety Instructions  
This device has been tested and left the factory in perfect technical condition. To  
maintain this condition and to ensure safe, trouble-free operation, the user must  
follow the instructions and warnings provided in this operating manual.  
Device safety  
The Dry Block Thermostat DZ 003 complies with the safety regulations according  
to the standard DIN EN 61010-1.  
The device meets the EMC requirements for laboratory devices according to the  
standard DIN EN 61326.  
4.  
Disposal  
Diaglobal GmbH will take back and dispose of units that are no longer needed or  
cannot be repaired, free of charge.  
Edition 2021-01  
5
5.  
General information about the Dry Block Thermostat  
In order to carry out kinetics tests more efficiently in the laboratory, it is  
necessary to preheat the samples before measurement. In addition, the reagents  
must also be kept at incubation temperature during a series of measurements.  
For this purpose, a small and handy dry block thermostat was developed as a  
stand-alone system in addition to the Diaglobal Photometers.  
The features in detail are:  
Temperature unit of 37 °C with an accuracy of 0.2 °C  
12 positions for round cuvettes  
Indication of temperature control by LED  
Heating up in 5 minutes per cuvette filled with 1000 L  
Power supply:  
AC-Adapter:  
12 VDC / 15 VA  
110 - 240 VAC 50/60 Hz  
6.  
Delivery and Installation  
Delivery  
After carefully unpacking the device, check whether it is in perfect condition.  
Also, check if it is complete according to the delivery note. The box contains the  
following items:  
Dry Block Thermostat and AC-Adapter  
The packaging materials must be stored carefully in case an item needs to  
be returned. Notify your dealer immediately if any defects are found.  
Installation  
Connect the AC-Adapter to the mains.  
The operating voltage range is between 110 VAC and 240 VAC at 50/60 Hz.  
Plug the connector into the socket on the backside of the Dry Block Thermostat.  
The Dry Block Thermostat DZ 003 is switched on with the red switch on the front  
of the device.  
After a few seconds, the green LED flashes. The red LED shows a continuous  
light.  