MYSON Unisenza Plus Thermostat Instruction Manual
Unisenza Plus - Thermostat
Installation and user manual
Admin setting
EN
BOOST
BOOST
BOOST
SYS MODE
SCHEDULE
USER SET
MENU
MENU
ADMIN SET
LANGUAGE
3
1
2
The editable settings are:
Select temperature display interval at 0.5°C(1°F) or 0.1°C
(0.2°F).
Temp disp
Select valve protection mode On or Off. If the relay is not
turned On for a week, the thermostat will turn On the heat-
ing to move the actuators for less than 3 minutes time, to
avoid the valve getting stuck or jamming.
Vlv prot
(available when SYS MODE is “HEAT”): algorithm designed
for underfloor heating (for heating systems with high inertia).
Tpi ufh
(available when SYS MODE is “HEAT”): algorithm designed
for radiator heating.
Tpi rad
Control
(available when SYS MODE is “HEAT”): algorithm for elec-
tric heating (for heating systems that heat up quickly an
cool down quickly).
Select which
control algorithm Tpi elec
mode is used for
room tempera-
ture control
Span ¼° c (span ½° f) Permanent deviation of temperature in P Mode.
Span ½° c (span 1° f)
Permanent deviation of temperature in P Mode.
Set minimum HEATING set point (5°C to 35°C).
Set minimum COOLING set point (5°C to 35°C).
Set maximum HEATING set point (5.5°C to 37°C).
Set maximum COOLING set point (5.5°C to 37°C).
Heat
Cool
Heat
Cool
Min sp
Max sp
32