Milesight WT101 Smart Radiator Thermostat User Guide
Examples:
1. Automatic Temperature Control periodic packet: report as reporting interval (10 minutes by
default).
017564 0467e600 03670701 0b903a02 09903a02
Channel
01
Type
75
Value
Channel
03
Type
67
Value
Temp: 07 01=>01
07=263*0.1=26.3°C
Value
64=>100%
Channel
Type
Value
Channel
Type
Target Temp: e6
00=>00 e6=230
*0.1=23°C
Motor Stroke: 3a
02=>02 3a=570
04
67
09
90
Channel
0b
Type
90
Value
Motor Position: 3a
02=>02 3a=570
2. Valve Opening Control periodic packet: report as reporting interval (10 minutes by default).
017564 03670f01 05925f 0b901c00 09904002
Channel
01
Type
75
Value
64=>100%
Value
Channel
03
Type
67
V
a
l
u
e
Temp: 0f 01=>01
0f=271*0.1=27.1°C
Value
Channel
05
Type
92
Channel
09
Type
90
Motor Stroke: 40
02=>02 40=576
5f=>95%
Channel
0b
Type
90
Value
Motor Position: 1c
00=>00 1c=28
3. Motor calibration packet: report when the motor start calibrating.
08e500 09903a02
Channel
08
Type
e5
Value
Channel
09
Type
90
Value
Motor Stroke: 3a
02=>02 3a=570
00=success
4. Open Window Detection: reports when detecting the window open or returns back to normal
status.
070001 03679600
Channel
07
Type
00
Value
Channel
03
Type
67
Value
Temperature: 96 00 =>00
96 = 150 * 0.1 = 15 °C
01=open
5. Freeze Protection: report when freeze protection is triggered or released.
22
| General | Details |
|---|---|
| Name | Milesight WT101 Smart Radiator Thermostat User Guide |
| Make | Milesight |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.4 MB |

Milesight WT201-868M Smart Thermostat User Guide

Milesight WT201 Airteq Smart Thermostat User Guide

Milesight WT201 Smart Thermostat User Guide