Milesight WT101 Smart Radiator Thermostat User Guide
Parameters
Description
Set target environment temperature. The device will adjust the valve
every 10 minutes if the gap between target temperature and current
temperature is more than tolerance value.
Target Temperature
Target Temperature
Tolerance
Set the tolerance value between target temperature and current
temperature.
Target Temperature
Regulation Range
Set the range for control knob to adjust the target temperature. Max
range: 16 - 35 °C, min range: 5 - 15 °C, default range: 10 - 28 °C.
When the device detects the temperature drops over cooling rate, it will
stop temperature control and report open window status; when the
device detects the temperature rising for 10 minutes or reaching target
temperature, it will start temperature control and report normal status.
Set the detecting condition of window open.
Open Window
Detection
Cooling Rate
Stop temperature
control for..
The device will start temperature control even it still detects the
window open after this interval.
Valve Opening Control: control valve opening status to adjust the temperature. 0% means valve
is all closed and 100% means valve is all open. When using this mode, the valve opening
percentage can be set via ToolBox App, control knob or downlink command.
14
| General | Details |
|---|---|
| Name | Milesight WT101 Smart Radiator Thermostat User Guide |
| Make | Milesight |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.4 MB |

Milesight WT201-868M Smart Thermostat User Guide

Milesight WT201 Airteq Smart Thermostat User Guide

Milesight WT201 Smart Thermostat User Guide

Milesight WT30x Smart Fan Coil Thermostat User Guide