LUTRON 653 Right Thermostat Control Datasheet

Application Note #653  
Number of HVAC Zones  
It is important to verify how many zones are in the HVAC system. In a retrofit application, this can easily be done by counting  
the number of thermostats currently installed. This is important to determine the right Lutron control for the application.  
As seen in the table below, all Lutron thermostat controls can control a single HVAC zone. For example, an application with  
3 HVAC zones will need three Lutron thermostat controls.  
Maximum...  
SMC55 Controller L-HWLV2-WIFI  
Zones per thermostat control  
Lutron flush-mount wired sensors per zone  
1
1
1
N/A  
There is a limit of 32 Palladiom thermostats per QS link even though the overall device limit is 99 devices per QS link.  
Each SMC55 controller requires one HomeWorks Palladiom thermostat. Each HomeWorks Palladiom thermostat counts  
as one device on the QS link. Up to four Palladiom thermostats can be used in a single zone (one master thermostat and  
three companion thermostats).  
Some multi-zone systems use a non-Lutron zone/damper controller to manage multiple zones throughout the house. Lutron  
thermostat controls are compatible with these zone/damper controllers, often through a third-party interface.  