Home > Lutron > LUTRON 653 Right Thermostat Control Datasheet

LUTRON 653 Right Thermostat Control Datasheet

Application Note #653  
Identifying HVAC Equipment (continued)  
Locate the HVAC Equipment Installation Manual (continued)  
Control wiring is normally found later in the installation manual. The installation manual will demonstrate how to connect  
the equipment to indoor thermostats. The connections that the thermostat requires will indicate the potential for a Lutron  
thermostat control to be used as an alternative in the same application. The wire connections will also reveal if the system  
uses a proprietary communication protocol between the controls and the HVAC equipment. If this is the case, the use of any  
Lutron or third-party alternative is ruled out. See below for examples of connection diagrams in installation manuals.  
Figure 2 displays typical thermostat connections from the HVAC equipment to the control.  
Figure 2 - Example Wiring Diagrams (standard)  
Figure 3 shows an example of an air conditioner/heat pump that has the capability of using a proprietary communication  
protocol between the HVAC equipment and a special control unit. Since this uses a proprietary communication protocol  
over terminal D, the Lutron thermostat control would not be able to control this application directly. In some cases, as with  
the equipment featured below, an auxiliary device can be added for the implementation of standard 24 V-, non-proprietary  
controls such as Lutron thermostats. It is important to determine if this is the case before proceeding and it will often be  
noted in the installation manual for the HVAC equipment.  
Figure 3 - Example Wiring Diagram (proprietary, not compatible)  
Continued on next page...  