Home > KINGHOME > KINGHOME WK-010WC1 Smart Thermostat Owner’s Manual

KINGHOME WK-010WC1 Smart Thermostat Owner’s Manual

Owner's Manual  
No.  
5
Name  
Instruction  
Y
G
Outdoor compressor gear  
Indoor fan  
6
7
HUM  
W
Humidification equipment signal port  
Primary furnace equipment signal port  
8
9
W2/AUX  
C
Secondary furnace equipment or electric heater signal port  
24V Common wire  
10  
11  
12  
R
24V Power supply  
H1/H2  
Communication signal port  
Extended temperature sensor interface for detecting outdoor ambient  
temperature.  
13  
S1/S2  
NOTES:  
(1)  
The current parameters of L, ERV, O/B, DH, Y, G, HUM, W, W2/AUX, C,  
R: rated current≤1A, 24V~@60Hz;  
(2)  
Whether the four-way valve type of the unit is cooling energization or  
heating energization, it is connected to the O/B signal port, and O or B  
should be selected according to the four-way valve type at the system  
setting;  
(3)  
(4)  
Other terminals are connected according to unit requirements.  
Communication Wire Selection :  
Cord length  
Cord type  
Cord size (mm2)  
Remark  
L(feet)  
Light/ordinary  
PVC sheathed  
twisted-copper cord  
2×0.75~  
2×1.25  
The total length of communication  
cables can't exceed 30m.  
L≤98.4  
4
GeneralDetails
NameKINGHOME WK-010WC1 Smart Thermostat Owner’s Manual
MakeKINGHOME
LanguageEnglish
FiletypePDF (Download)
File size0.52 MB
Download PDF