KINGHOME WK-010WC1 Smart Thermostat Owner’s Manual
Owner's Manual
No.
5
Name
Instruction
Y
G
Outdoor compressor gear
Indoor fan
6
7
HUM
W
Humidification equipment signal port
Primary furnace equipment signal port
8
9
W2/AUX
C
Secondary furnace equipment or electric heater signal port
24V Common wire
10
11
12
R
24V Power supply
H1/H2
Communication signal port
Extended temperature sensor interface for detecting outdoor ambient
temperature.
13
S1/S2
NOTES:
(1)
The current parameters of L, ERV, O/B, DH, Y, G, HUM, W, W2/AUX, C,
R: rated current≤1A, 24V~@60Hz;
(2)
Whether the four-way valve type of the unit is cooling energization or
heating energization, it is connected to the O/B signal port, and O or B
should be selected according to the four-way valve type at the system
setting;
(3)
(4)
Other terminals are connected according to unit requirements.
Communication Wire Selection :
Cord length
Cord type
Cord size (mm2)
Remark
L(feet)
Light/ordinary
PVC sheathed
twisted-copper cord
2×0.75~
2×1.25
The total length of communication
cables can't exceed 30m.
L≤98.4