Special Features  
Auto Fan  
LCD Error Code  
When the auto fan mode is selected,  
the fan speed will vary depending on  
the temperature difference between the  
temperature set-point and the room  
temperature.  
The following error code will be  
displayed on the LCD when the system  
detects one of the following faults has  
occurred.  
LCD Error Code  
Temperature  
Fan Speed  
Difference  
Indoor temperature sensor out of  
E1  
order. System will shut down.  
The fan operates on High  
level  
>3ºF  
>1ºF  
<-1ºF  
Evaporator temperature sensor out  
E2  
of order. System will shut down.  
The fan operates on Med  
level  
Loss of communication between the  
E3 thermostat and control box. System  
will shut down.  
The fan operates on Low  
level  
Condenser temperature sensor out  
E4  
of order. System will shut down.  
Compressor Time Delay  
Outdoor temperature sensor out of  
E5  
order. System will shut down.  
A time delay of approximately three  
minutes occurs any time the compressor  
is required to begin the cooling cycle.  
Insufficient low level of +12V power  
lo  
supply. System will shut down.  
NOTE: The time delay occurs  
Programmable Timers  
automatically after a mode is selected  
or a power event occurs to ensure  
pressure in the compressor is equalized  
appropriately, to prevent damage.  
The multizone thermostat can store up  
two timer for each zone. The timers  
can be used to assign start and finish  
of two unique mode and fan selections.  
For instance, program 1 is used to set a  
day condition COOL mode and auto fan  
speed to begin at 8:00AM, program 2 is  
used to set an evening/night condition  
AUTO mode and low fan speed to begin  
at 7:00PM.  
Power Interruption  
In the event the power to the air  
conditioner or controller is interrupted,  
the system will restart automatically  
with the last status and operational  
parameter set-points once the power is  
restored.  
12  
GeneralDetails
NameFURRION FACW12ZA-BL Multi Zone Wall Thermostat Instruction Manual
MakeFURRION
LanguageEnglish
FiletypePDF (Download)
File size0.48 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
FURRION FACW10ESSA-BL Standard Single Zone Wall Thermostat User Guide
FURRION FACW10ESSA-BL Standard Single Zone Wall Thermostat User Guide

FURRION FACW12ZA-BL Multi Zone Wall Thermostat Instruction Manual