FURRION FACW12ZA-BL Multi Zone Wall Thermostat Instruction Manual
Special Features
Auto Fan
LCD Error Code
When the auto fan mode is selected,
the fan speed will vary depending on
the temperature difference between the
temperature set-point and the room
temperature.
The following error code will be
displayed on the LCD when the system
detects one of the following faults has
occurred.
LCD Error Code
Temperature
Fan Speed
Difference
Indoor temperature sensor out of
E1
order. System will shut down.
The fan operates on High
level
>3ºF
>1ºF
<-1ºF
Evaporator temperature sensor out
E2
of order. System will shut down.
The fan operates on Med
level
Loss of communication between the
E3 thermostat and control box. System
will shut down.
The fan operates on Low
level
Condenser temperature sensor out
E4
of order. System will shut down.
Compressor Time Delay
Outdoor temperature sensor out of
E5
order. System will shut down.
A time delay of approximately three
minutes occurs any time the compressor
is required to begin the cooling cycle.
Insufficient low level of +12V power
lo
supply. System will shut down.
NOTE: The time delay occurs
Programmable Timers
automatically after a mode is selected
or a power event occurs to ensure
pressure in the compressor is equalized
appropriately, to prevent damage.
The multizone thermostat can store up
two timer for each zone. The timers
can be used to assign start and finish
of two unique mode and fan selections.
For instance, program 1 is used to set a
day condition COOL mode and auto fan
speed to begin at 8:00AM, program 2 is
used to set an evening/night condition
AUTO mode and low fan speed to begin
at 7:00PM.
Power Interruption
In the event the power to the air
conditioner or controller is interrupted,
the system will restart automatically
with the last status and operational
parameter set-points once the power is
restored.
12
| General | Details |
|---|---|
| Name | FURRION FACW12ZA-BL Multi Zone Wall Thermostat Instruction Manual |
| Make | FURRION |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.48 MB |

FURRION FACW10ESSA-BL Standard Single Zone Wall Thermostat User Guide