fontastic RAVL Wireless Radiator Thermostat User Manual
GB
GB
Change value from
to
Menu item
Function
Value setting
Default value
Factory settings
Switched off
and press
Normal
twice to reset
Active when temperature set
from 5-25°C
Window open
detection
Switched off
Valve closure
adjustment
Normal
If active, 2nd setting Duration
of the function in minutes
Strong closing
Automatic key
lock after 10
minutes
Switched off
No liability is accepted for any damage caused by incorrect operation.
If you need technical support, please contact our support team at our
website support.fontastic.eu or check the FAQs in the FontaHome app
Switched off
Switched on
Minimum
adjustable
temperature
1-15°C
5°C
Safety instructions
• Do not dismantle the unit.
Maximum
adjustable
temperature
• Do not immerse the unit in water and protect it from moisture.
• Never use the appliance if it has visible damage.
• Do not operate the unit outdoors or in rooms with high humidity.
16-70°C
35°C
Boost mode
Duration
100-900 seconds
(in steps of 100 seconds)
300 Seconds
Valve position Displays the valve position in
Technical data thermostat
• Batteries: 2xAA
• Valve connection: M30x1.5
• Adjustable temperature: 1°- 70°C
• Frequency band: 2.4GHz (Zigbee)
• Radio range: Up to 30m (unobstructed)
display
percent
Threshold value from when the
valve is opened/closed
0.5-1.5°C
Threshold
valve setting
1°C
Normal
Display
rotation
Normal
180° rotated
We hereby declare that this appliance bears the CE marking in
accordance with the regulations and specifications. It therefore
complies with the essential requirements of the RED Directive
2014/53/EU and RoHS Directive 2011/65/EU.
You can find the complete declaration of conformity
Intelligent control
Valve adjust-
ment mode
Intelligent
control
Static control according to
temperature
29
30
| General | Details |
|---|---|
| Name | fontastic RAVL Wireless Radiator Thermostat User Manual |
| Make | fontastic |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.36 MB |