Fantini cosmi C820RQ Dual Power Room Thermostat Instruction Manual
C820RQ
Energy class
When the TPI adjustment is active, it is necessary to set the energy class of the building
for enabling the optimisation of the system's runtimes.
Default parameter = A4
A4, A3, A2, A1, B, C, D, E, F, G
Function only available for TPI adjustment.
Type of emission terminals
If the TPI adjustment is activated, it is necessary to also set other related parameters.
The emission terminal identifies the final element of the heating/cooling system.
By setting the emission terminal, the values of the Proportional Band and the
Adjustment Period are automatically set (see the below table); however, they can
still be changed.
Emission terminal
Radiators
Fan coil
Proportional band [°C]
Setting period [min]
0.5
0.5
1
15
15
30
Floor
Default value = 1
1 = Radiators
2 = Fan Coil
3 = Floor
Function only available for TPI adjustment.
TPI Adjustment Period
The TPI Adjustment Period indicates the duration of a system on+off cycle. This
period depends on the type of the emission terminal.
The values for the Adjustment Period are set automatically by setting the emission
terminal (see table P13); however, they can still be changed.
Default value = 15
5 ÷ 60 min
Function only available for TPI adjustment.
ENG
35 -
| General | Details |
|---|---|
| Name | Fantini cosmi C820RQ Dual Power Room Thermostat Instruction Manual |
| Make | Fantini Cosmi |
| Language | English |
| Filetype | PDF (Download) |
| File size | 3.33 MB |

Fantini Cosmi CH180-230V Touch Screen Programmable Thermostat Instructions

Fantini Cosmi CH121E Flush Mounting Thermostat User Manual

Fantini Cosmi C800WIFI Programmable LED Thermostat Instruction Manual

Fantini Cosmi C820RQ LED Thermostat User Manual

Fantini Cosmi CH141E Battery Operated Weekly Programming Thermostat Owner’s Manual