1 TECHNICAL DATA
Power supply
230 V - 50 Hz
2 AA 1.5 V alkaline batteries
Battery life
> 1 year
Adjustment
ON / OFF or TPI
1 W
Max. power consumption
5 / 10 s from last press; always ON
(only at 230V power supply)
LED switch-off
Temperature adjustment range
Measurement range / Room T display
Temperature display
2 ÷ 40 °C; increments of 0.1 °C
-9 to +50 °C; resolution 0.1 °C
Celsius
Relay output with changeover dry contacts
Microdisconnection
5(3)A 230 Vca
1 B.U.
Nominal conductor wire gauge
for flexible cables
0.5 to 1 mm2
Minimum adjusting differential
Thermal gradient of reference
Maximum room temperature
Storage temperature
Software
STD; (0.3 ÷ 5) °C
4 K/h
45°C
-10 ÷ +60 °C
Class A
Class II
IP32
Insulation class
Protection rating
Degree of pollution
2
Wall-mounting or on a Flush-mounting box
type 500-502-503
Mounting
98 x 98 x 20 mm (square base)
125 x 98 x 20 mm (rectangular base)
Dimensions
Weight
0.100 kg
Compliant with standards: EN 60730-1 and parts two;
Directive 2014/30/EU (EMC); Directive 2014/35/EU (LVD);
ErP classification: ErP Class IV, 2 % (Reg. EU 811/2013 - 813/2013).
Product manufactured in Italy.
ENG
- 22
| General | Details |
|---|---|
| Name | Fantini cosmi C820RQ Dual Power Room Thermostat Instruction Manual |
| Make | Fantini Cosmi |
| Language | English |
| Filetype | PDF (Download) |
| File size | 3.33 MB |

Fantini Cosmi CH180-230V Touch Screen Programmable Thermostat Instructions

Fantini Cosmi CH121E Flush Mounting Thermostat User Manual

Fantini Cosmi C800WIFI Programmable LED Thermostat Instruction Manual

Fantini Cosmi C820RQ LED Thermostat User Manual

Fantini Cosmi CH141E Battery Operated Weekly Programming Thermostat Owner’s Manual