11  
insert the second receiver into a mains socket.  
Press the button on the receiver 3 times the blue LED lights up,  
when the receiver is detected, the blue led goes out,  
Proceed similarly with the connection of the subsequent receivers, then press the  
button on the transmitter board. The pairing mode is ended.  
Caution! Pairing mode is only available for 10 minutes after connecting the receiver  
to the mains, resetting it, or installing batteries in the thermostat!  
Factory-established pairs are paired, however, pairing may be repeated if necessary.  
SELECTING OPERATING MODE  
While holding the "B" button pressed, insert the receiver into a mains socket. Depending on  
the mode set, the green or red LED lights up. Each time the button is pressed, the operating  
mode changes. When you select the mode, the receiver restores operation.  
Green normally open mode (COM NO). It is the mainly used operation mode. While the  
device operation indicator is active, the output cables are shorted.  
Red normally closed mode (COM NC). While the device operation indicator is active, the  
output cables are opened.  
Caution! The factory default setting is (COM-NO).  
9. FIRST START  
When inserted into the mains socket, the receiver indicates the relay operating mode. A flash  
of green LED normally open mode (COM-NO), a flash of red normally closed mode (COM-  
NC).  
Any change in the status of the thermostat (switching the heating on/off) is made immediately  
by the receiver, while the confirmation that the radio signal is received from the transmitter is  
repeated every 15 minutes.  
RADIO SIGNAL STRENGTH  
The radio signal strength is indicated together with the reception of the transmitter signal.  
Radio signal reception is indicated in green. LED flashing three times stands for a very strong  
range, twice for a strong range, and once for sufficient range.  
NO RADIO COMMUNICATION  
If the communication between the thermostat and the receiver is interrupted (e.g. discharged  
batteries) and if this condition lasts for 60 minutes (no response from the receiver), the  
receiver switches to the frost protection mode. The heating device will be switched on every 3  
hours for 20 minutes to prevent the rooms from being cooled down. At the time of re-  
establishing communication (e.g. replacement of batteries), the receiver will automatically  
switch the system off and resume operation.  
If there is no radio communication, the green LED flashes rapidly.  
CONTINUOUS OPERATION OF HEATING DEVICE (MAN)  
In the event of system failure, it is possible to manually switch on the heating. Move the switch  
on the RX receiver to the MAN position. Such status is indicated by a rapid flashing of the red  
LED.  
RECEIVER SIGNALING TABLE.  
Function  
Pairing  
Signaling  
Blue  
Reception of radio signal  
No radio communication  
The heating/air-conditioning device is switched on  
Manual mode  
Green  
Green flashing  
Red  
Red flashing  
GeneralDetails
NameEUROSTER 2026TXRX Air Conditioning Thermostat Instruction Manual
MakeEUROSTER
LanguageEnglish
FiletypePDF (Download)
File size0.62 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EUROSTER 4040 Smart Programmable Thermostat User Manual
EUROSTER 4040 Smart Programmable Thermostat User Manual
EUROSTER 2006TXRX Wireless Programmable Thermostat Installation Guide
EUROSTER 2006TXRX Wireless Programmable Thermostat Installation Guide

EUROSTER 2026TXRX Air Conditioning Thermostat Instruction Manual