Home > EPH CONTROLS > EPH Controls RF1A Programmable RF Thermostat Instruction Manual

EPH Controls RF1A Programmable RF Thermostat Instruction Manual

Page 1 of 1  
Operating Instructions  
RF1A - Wireless Receiver with TRFPi2  
Contents  
1. Specifications & wiring  
2. Mounting  
3. Installation  
4. Button / LED description  
5. Resetting the RF1A receiver  
6. To connect the TRFPi2 thermostat to an  
RF1A receiver  
CAUTION!  
Before commencing any work on the electrical  
connections, you must first disconnect the device from  
the mains. None of the 230V connections must be live  
until the installation has been completed and the housing  
is closed. Only qualified electricians or authorised service  
staff are permitted to open the terminal box.  
7. To disconnect the TRFPi2 thermostat from an  
RF1A receiver  
There are parts that carry mains voltage behind the cover.  
The terminal box must not be left unsupervised when  
open. (Prevent non specialists and especially children  
from gaining access to it.)  
Important: Keep this document  
Ensure that this wireless enabled receiver is installed 1  
metre from any metalic object, television, radio or wireless  
internet transmitter.  
Prior to operation, it is neccessary to complete all  
required settings described in this section.  
1. Specifications & wiring  
4. Button / LED description (Continued)  
Manual override: This button will manually override the system.  
Power Supply: 230 Vac 50Hz  
Contact Rating: 250 Vac 10(3)A  
Ambient Temp: 0~50°C  
Class II appliance  
Pollution degree 2: Resistance to  
voltage surge 2500V; as per EN 60730  
Wireless connect indicator: This LED will flash on receiving wireless signals.  
If it is constantly ON, the RF1A receiver has been disconnected from the  
wireless thermostat.  
Internal wiring diagram for RF1A  
5. Resetting the RF1A receiver  
RESET  
Press the  
button located on the side of the receiver. Within 2  
3
2
1
L
L
N
N
seconds, press the ‘Connectbutton. The RF1A receiver is now reset.  
COM  
ON  
OFF  
6. To connect the TRFPi2 thermostat to an RF1A  
receiver  
* If mains voltage output is required,  
MAINS  
SUPPLY  
Please note, If you are installing a CombiPack2 the TRFPi2 thermostat and  
the RF1A receiver will have a pre-established RF connection so it is not  
necessary to carry out the RF connection process below.  
terminals L & 2 must be electrically linked.  
2. Mounting  
On the RF1A receiver:  
The RF1A receiver should be wall mounted in an area within 20 metres  
distance of the wireless thermostat.  
Press the  
button. The red and green light will begin to flash.  
Connect  
It is important that the receiver is mounted more than 1 metre away from  
metal objects as this will affect communication with the thermostat.  
On the TRFPi2 thermostat:  
Connect  
Press the  
button.  
The receiver should also be installed at least 1metre from any electronic  
devices such as radio, TV, microwave or wireless network adaptor.  
The thermostat will begin to search through the RF channels.  
Once an RF connection has been established the thermostat will show ‘r01’  
The unit can be fitted to:  
1. Recessed conduit boxes  
2. Surface mounting boxes  
on the LCD screen.  
Press the ‘OKbutton to finish the process.  
The thermostat is now connected to the RF1A receiver.  
RF Connectappears on the screen.  
3. Installation  
Slacken the fastening screw on the bottom of the receiver with a philips  
screwdriver.  
7. To disconnect the TRFPi2 thermostat from an  
The receiver is hinged and can be opened 180 degrees. Mount the unit as  
described in section 2. Wire the unit as described in section 1. Close the  
receiver and tighten the fastening screw.  
RF1A receiver  
On the TRFPi2 thermostat:  
Connect  
Press the  
button.  
4. Button / LED description  
The thermostat will begin to search through the RF channels.  
Press and hold the standby button for 10 seconds.  
AdL’ & AdHwill flash intermittently on the screen of the thermostat.  
Press the ‘OKbutton twice to complete the unpairing process.  
The thermostat TRFPi2 is now disconnected from the receiver RF1A.  
Note: RF Connect may remain on the screen for 1-2 minutes.  
System ON  
(Green LED)  
Connect button  
Manual override  
Reset button  
Wireless connect  
indicator (Red LED)  
On the RF1A receiver:  
RESET  
Press the  
button and immediately press the  
button.  
Connect  
The red and green lights will flash quickly followed by a solid red light.  
The RF1A receiver is now disconnected from the TRFPi2 thermostat.  
Wireless connect: Once voltage has been applied this button may be  
pressed to initialise the pairing process with the wireless thermostat. Once  
pressed the red and green LED will begin to flash.  
EPH Controls Ireland  
EPH Controls UK  
20230123_RF1A-TRFPi2_OpIns_PK  
GeneralDetails
NameEPH Controls RF1A Programmable RF Thermostat Instruction Manual
MakeEPH CONTROLS
LanguageEnglish
FiletypePDF (Download)
File size0.11 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide
EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide
EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual
EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual
EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual
EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual
EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual
EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual
EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual
EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual
EPH Controls CDT2-24 24V Room Thermostat Installation Guide
EPH Controls CDT2-24 24V Room Thermostat Installation Guide
EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual
EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual
EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual
EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual
EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions
EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions
EPH CONTROLS RFRA RF Room Thermostat Installation Guide
EPH CONTROLS RFRA RF Room Thermostat Installation Guide

EPH Controls RF1A Programmable RF Thermostat Instruction Manual
Get the free PDF manual for the EPH Controls RF1A Programmable RF Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

EPH Controls RF1A Programmable RF Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Operating instructions for RF1A - Wireless Receiver with TRFPi2. Specifications & wiring include power supply, contact rating, and ambient temperature. Mounting instructions specify the RF1A receiver should be wall mounted within 20 meters of the wireless thermostat. Installation steps involve loosening a fastening screw and wiring the unit as described. Button/LED descriptions detail functions such as manual override and wireless connect indicators. Resetting the RF1A receiver requires pressing specific buttons in sequence. Connecting the TRFPi2 thermostat to the RF1A receiver involves pressing the connect button and ensuring proper distance from metal objects. Disconnecting the TRFPi2 thermostat from the RF1A receiver includes pressing and holding the standby button. Important safety cautions include disconnecting the device from mains before electrical work and ensuring the terminal box is not left unsupervised when open. The document emphasizes keeping it accessible for reference during installation and operation.