Home > ENGO CONTROLS > ENGO CONTROLS EONE-BATW, EONE-BATB Internet Controlled Thermostat User Guide

ENGO CONTROLS EONE-BATW, EONE-BATB Internet Controlled Thermostat User Guide

Installer parameters  
4
5
6
Binding thermostat with the ECB62-ZB wireless control box  
Default  
value  
Pxx  
Function  
Value  
Desription  
Make sure that the ECB62-ZB control box and thermostat are in the same ZigBee network (they are added to  
the same gateway) and the POWER LED lights up blue.  
12h  
24h  
12 hour  
24 hour  
Heating  
P01  
Clock format  
24h  
1
P02  
Heating/Cooling Selection  
Cooling  
TPI for Underfloor Heating  
TPI for Radiators  
TPI for Electrical Heating  
SPAN +/-0,1°C  
TPI UFH  
TPI RAD  
TPI ELE  
HIS 0.2  
HIS 0.4  
HIS 0.6  
HIS 0.8  
HIS 1.0  
HIS 2.0  
HIS 3.0  
HIS 4.0  
3
Name the device  
and click„Done”  
The thermostat has been  
installed and displays the  
main interface.  
On the controller screen globe  
icon appeared stating that  
he has been he added to the  
ZigBee network.  
TPI UFH  
for heating  
HIS 1.0 for  
cooling  
SPAN +/-0,2°C  
P03  
Control algorithm  
SPAN +/-0,3°C  
SPAN +/-0,4°C  
2
1
SPAN +/-0,5°C  
2
SPAN +/-1,0°C  
SPAN +/-1,5°C  
In order to correctly link thermostat with the control box, first select the zone in the control box with the SELECT  
button (1) (zone which you want to link with thermostat). The LED (2) will flash 3 times for the selected zone.  
Confirm your selection by clicking PAIR button (2). The LED (2) will flash green with the previously selected  
zone - binding process has started, it is active for 10 minutes and during this time you can link thermostat  
with the selected zone.  
SPAN +/-2,0°C  
If the thermostat indicates wrong temperature, you can correct it by  
max 3.5°C"  
P04  
Offset temperature  
-3.5°C do +3.5°C  
5°C - 45°C  
0°C  
Binding thermostat with the module/relay  
P05  
P06  
"Minimum setpoint"  
"Maximum setpoint"  
Minimum heating / cooling temperature that can be set  
5°C  
Make sure that the module/relay and thermostat are in the same ZigBee network (they are added to the  
same gateway).  
5°C - 45°C  
Maximum heating / cooling temperature that can be set  
Disable  
35°C  
2
3
4
1
2
3
4
External sensor as a floor sensor  
External sensor as an air sensor  
Occupnacy sensor (ON/OFF volt free input)  
2
P07  
P08  
S1/S2 Input  
1
1
5x  
Maximum floor temperature for heating  
(function active when P07=2)  
In order to protect the floor, the heating will be turned off, when the  
temperature of the floor sensor rises above the maximum value.  
5°C - 45°C  
35°C  
or  
Minimum floor temperature for heating  
(function active when P07=2)  
In order to protect the floor, the heating will be switched on, when the  
temperature of the floor sensor drops below the minimum value.  
P09  
P10  
P11  
5°C - 45°C  
5°C - 45°C  
5°C - 45°C  
10°C  
15°C  
7°C  
On the EONE thermostat,  
hold and buttons until binding functionprocess of linking  
the "bind"message appears. thermostat with control box is active.  
Release the keys,  
The "binding" process takes  
up to 300 seconds.  
Maximum floor temperature for cooling  
(function active when P07=2)  
In order to protect the floor, cooling will be switched on, when the  
temperature of the floor sensor exceeds the maximum value.  
5x  
To properly link thermostat with the module/relay  
first click quickly the button on the device 5 times.  
The LED diode will start flashing slowly on red, which  
means the device is in binding mode.  
On the EONE thermostat, hold and buttons  
until the "bind" message appears.  
Minimum floor temperature for cooling  
(function active when P07=2)  
In order to protect the floor, cooling will be turned off, when the  
temperature of the floor sensor drops below the minimum value  
6
5
OFF  
This function helps to keep the floor warm, even if there is no heating  
demand from the room thermostat. This feature is available only for  
Heating Mode. User can select 5 levels of warm floor feature. Note that  
comfort warm floor function will activate heating for specified amount  
of time (in relation to Level setting choosen by user). Heating will be  
activated only if in the past 1 hour heating was OFF.  
ATTENTION:  
Level 1 = 7min  
Level 2 = 11min  
Level 3 = 15min  
Level 4 = 19min  
If the binding process fails, it  
must be repeated taking into  
account the distances between  
devices, obstacles and local  
radio signal interferences.  
P12  
Comfort warm floor  
OFF  
4
3
Level 5 = 23min  
ON  
OFF  
Function disabled  
Function enabled  
3
P13  
P14  
P15  
Valve protection  
Backlight brightness  
OFF  
50%  
NO  
After successfull binding operation  
„End”message will be displayed. successfully linked. Thermostat  
displays the main screen, icon  
Both devices have been  
10% - 100%  
Adjustable in the range from 10 to 100%  
Remember:  
NO  
PIN  
NO  
Function disabled  
Function enabled  
Function disabled  
Function enabled  
No action  
PIN Code for settings access  
Radio range can be  
increased by Engo  
ZigBee repeaters.  
Release the keys, binding function process of  
linking thermostat with control box is active.  
The "binding" process takes up to 300 seconds.  
"
" appeared on the screen  
indicating connection with the  
receiver (ECB62ZB in this case).  
Require a PIN to unlock the keys every time  
(function active when P15=PIN)  
P16  
CLR  
NO  
NO  
YES  
NO  
5
6
ATTENTION:  
Clear settings factory reset  
YES  
Factory Reset  
When the thermostat is binded with the module, the relay will turn off after 50 minutes,  
if the communication between the devices is lost.  
After successfull binding operation„End”  
message will be displayed. LED on the module  
will stop flashing.  
Both devices have been successfully linked.  
Thermostat displays the main screen, icon "  
appeared on the screenindicating connection with  
the receiver (module/relay in this case).  
Installer settings  
To enter installer parameters press and hold button for 3 seconds.  
Factory reset  
"
To RESET Thermostat to factory settings, hold down the and buttons until the FA message appears.  
Then release the keys. Thermostat will restart, restore default factory settings and displays the home  
screen. The device will be removed from the ZigBee network you will need to add/pair it again.  
2
1
ATTENTION:  
If the binding process fails, it must be repeated taking into account the distances between  
devices, obstacles and local radio signal interferences.  
SET  
3 sec.  
1
2
3
Remember:  
Radio range can be increased by Engo ZigBee repeaters.  
SET  
ATTENTION:  
Use or . button to move between parameters. Enter the parameter by . Edit the parameter using  
or . Confirm the new parameter value with the button.  
When the thermostat is binded with the module, the relay will turn off after 50 minutes,  
if the communication between the devices is lost.  
GeneralDetails
NameENGO CONTROLS EONE-BATW, EONE-BATB Internet Controlled Thermostat User Guide
MakeENGO CONTROLS
LanguageEnglish
FiletypePDF (Download)
File size0.53 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
ENGO Controls EONE230W Internet Controlled Thermostat User Guide
ENGO Controls EONE230W Internet Controlled Thermostat User Guide
ENGO CONTROLS EFAN-230W Fan Coil Thermostat User Guide
ENGO CONTROLS EFAN-230W Fan Coil Thermostat User Guide
ENGO CONTROLS FAN-24W 24V Fan Coil Thermostat User Guide
ENGO CONTROLS FAN-24W 24V Fan Coil Thermostat User Guide
ENGO CONTROLS EASY230W Non-Programmable Wired Thermostat User Guide
ENGO CONTROLS EASY230W Non-Programmable Wired Thermostat User Guide
ENGO CONTROLS EONE230 Internet Controlled Thermostat User Guide
ENGO CONTROLS EONE230 Internet Controlled Thermostat User Guide
ENGO CONTROLS EONEBATW, EONEBATB Internet Controlled Thermostat User Manual
ENGO CONTROLS EONEBATW, EONEBATB Internet Controlled Thermostat User Manual
ENGO Controls E901WIFI Internet Wireless Thermostat User Guide
ENGO Controls E901WIFI Internet Wireless Thermostat User Guide
ENGO CONTROLS EFAN-24W Fan Coil Thermostat User Guide
ENGO CONTROLS EFAN-24W Fan Coil Thermostat User Guide
ENGO CONTROLS EFAN-230W WIFI 230V Fan Coil Thermostat User Guide
ENGO CONTROLS EFAN-230W WIFI 230V Fan Coil Thermostat User Guide
ENGO CONTROLS E10-MBUSW, E10-MBUSB Wi-Fi MODBUS Thermostat User Guide
ENGO CONTROLS E10-MBUSW, E10-MBUSB Wi-Fi MODBUS Thermostat User Guide

ENGO CONTROLS EONE-BATW, EONE-BATB Internet Controlled Thermostat User Guide