Setting the room temperature
The room temperature can be increased/decreased manually by pressing the
touch button on the thermostat.
•
•
Press the “+” button to increase the temperature setpoint.
Press the “–” button to decrease the temperature setpoint.
NOTE:
•
•
Temperature can be adjusted in 0.5°C increments.
Max. and Min. temperature setpoint which can be set is based for the limit
In P4, if floor sensor is fitted, device will be in room temperature with floor limits
mode.
If the room temperature equals or exceeds the setpoint, and the floor temperature
is below the lower limit (min. guard), a demand is created, heating the room to
warm the floor, and the demand LED flashes white at 1 Hz.
If the room temperature is lower than the setpoint and the floor temperature
exceeds the upper limit (max. guard), the demand should be 0, control output
should be prevented, and the demand LED flashes white at 1 Hz.