elko One Matter Thermostat Owner’s Manual
Minimum floor limit
After setting floor probe type, you must set the minimum floor limit. It is lower limit
of the floor sensor.
To set floor limit:
1. Select menu 52 by pressing O touch button for > 1 s to enter the settings.
2. Press + or – touch button on the device to set the minimum limit.
3. Press the O touch button for > 1 s to confirm the selection.
NOTE:
•
•
•
The temperature limit ranges from 10° C to 39° C.
Each “+/–” tapping will increase or decrease the temperature by 1° C.
When the minimum floor limit is set, it changes the minimum floor control
Maximum floor limit
After setting minimum floor limit, you must set the maximum floor limit. It is upper
limit of the floor sensor.
To set maximum guard temperature:
1. Select menu 53 by pressing O touch button for > 1 s to enter the settings.
2. Press + or – touch button on the device to set the maximum limit.
3. Press the O touch button for > 1 s to confirm the selection.
NOTE:
•
•
•
The temperature limit ranges from 11° C to 40° C.
Each “+/–” tapping will increase or decrease the temperature by 1° C.
When the maximum floor limit is set, it changes the maximum floor control
14
DUG_Matter Thermostat_ELKO-01