Installation Plan A  
Our products are designed to comply with the recommended codes of practice and is to be installed and serviced by competent  
persons in accordance with the relevant wiring regulations.  
!
Warning: Before any installation or maintenance, ensure that the electrical supply is switched off at the breaker.  
The receiver needs to be installed in the boilers vicinity, and within the desired wireless networks signal area.  
The Thermostat can be installed anywhere within range of the receiver.  
Router’s  
position  
Receiver’s  
position  
Boiler  
Note: Distance between thermostat and receiver cannot be greater than 100m (open field).  
1
Install receiver on the wall  
1
2
3
Install the backplate  
onto the wall.  
Clip the receiver  
onto the backplate  
4
Open backplate from the top  
Installation Plan A Wiring  
Complete  
2
Black & Grey  
Control  
Cables  
Brown & Blue  
Power Supply  
Cables  
Potential Free Relay  
1
Boiler type  
selection;  
The  
TH TH  
N
L
Thermostats  
output between  
N/C & N/O,  
Typically N/O  
Boiler  
Black & Grey  
Control  
Cables  
Brown & Blue  
Power Supply  
Cables  
230V Relay  
2
Boiler type  
selection;  
This boiler type  
can only be  
N/O  
LS LR  
N
L
Boiler  
Page: 7  