Danfoss TP5001B-TP5001RF Programmable Room Thermostat User Guide
User Guide
TP5001 Programmable Room Thermostats
7
Frost Protection Temperature
•
You can switch the thermostat OFF (Standby) by alternately pressing . In OFF (Standby) mode, the thermo-
stat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls
below this temperature (5 °C by default).
•
The frost protect icon and current temperature will be displayed.
8
Advanced Programmable Timer
The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic
comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is
not required.
Example below for 5/2 day setup, 4 Temperature settings.
The function consists of 2 programs:
P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)
P2 with 4 events in 2 days (Sat. Sun.).
P1: Press for 3 secs to display Mo. Tu. We. Th. Fr.
P2: Sa. Su. are now shown in the display.
P1, Event 1:
P2, Event 1:
1. Use < or > to select the start hour.
2. Press to accept the setting.
3. Use < or > to set the minute.
4. Press to accept the setting.
5. Use < or > to select the temperature.
6. Press to accept the setting.
1. Use < or > to select the start hour.
2. Press to accept the setting.
3. Use < or > to set the minute.
4. Press to accept the setting.
5. Use < or > to select the temperature.
6. Press to accept the setting.
P1, Event 2-4:
P2, Event 2-4:
Repeat the Event 1 procedure for programming
Event 2-4.
Repeat the Event 1 procedure for programming
Event 2-4.
If schedule working mode is set to 24hr, only P1 program will be available, see parameter P01. Mo. to Su. will be
set together with the same times and temperatures.
The thermostat will continue the 4-event program based on the present time and day.
To set and change the room temperature temporarily:
1. Press < or > at any time to change the desired temperature value. SET is shown in the display.
2. When releasing the < or >, the display returns to showing the actual temperature. This temperature change is
only temporary and will be maintained only until the next programmed setting!
A default program provides timer control if the customer does not create own programs:
Days
Event 1
Start time
Event 2
Start time
Event 3
Start time
Event 4
Start time
Temp.
20° C
20° C
Temp.
15° C
15° C
Temp.
20° C
20° C
Temp.
15° C
15° C
Mo. - Fr.
Sa. - Su.
6:30
7:30
8:30
9:30
16:30
16:30
22:30
22:30
* 24hr mode default program same as Mo. - Fr. above.
Danfoss Climate Solutions
3
03/2023
BC306936081288EN-010201
| General | Details |
|---|---|
| Name | Danfoss TP5001B-TP5001RF Programmable Room Thermostat User Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.24 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide