Danfoss RAS-D2 Radiator Thermostat Installation Guide
Installation Guide
User Guide
Fitting the Sensor
Setting the desired room temperatures
1. Remove cap from valve
and turn sensor to
The desired room temperature is set by turning the head.
The temperatures obtained are approximately:
2. Press the sensor firmly
onto the valve. Sensor
horizontal: ensuring
Do not cover the thermostat
that the scale pointer is
at top. Sensor vertical:
ensuring that the scale
pointer is at the front.
The thermostat opens and closes as determined by the
temperature around it.Therefore the sensor must never be
hidden behind thick curtains, furniture, etc. Alternatively a
thermostat with remote sensor should be used.
Positive SHUT-OFF feature:
Theheadcanbeturnedpastthe*setting(aslightresistance
will be felt) to setting "0" at which point the water flow is
shutoffcompletely.Afteralsoshuttingthelockshieldvalve
theradiatormaybedrainedandremovedformaintenance
and decoration purposes.
3. Whilst holding the
sensor firmly on the
valve secure connection
by tightening the
Allen screw using the
enclosed key.
4. Set desired room
temperature.
Removing the Sensor
Loosen the Allen screw (3).
The sensor can now be separated from the valve.
This package contains
Sensor Chrome: 013G6170 or - Chrome/RAL 9016: 013G6176
and valve RA-FS - Chrome: 013G6282
What is a thermostatic radiator valve (TRV)?
... an explanation for householders.
TRVs sense the air temperature around them and regulate the flow of water through
the radiator which they are fitted to. They do not control the boiler.
They should be set at a level that gives you the room temperature you want. These set-
tings may have to be different in each room, and you should set the TRVs to suit each
room and then leave them to do their job.
Turning aTRV to a higher setting will not make the room heat up any faster. How quickly
the room heats up depends on the boiler size and setting, and the radiator size. Turning a TRV to a lower setting will
result in the room being controlled at a lower temperature, and saves energy.
TRVs need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture.
TRVs cannot turn off the boiler when the whole house is warm. To do that, you will need a room thermostat as well.
The radiator in the room with the room thermostat should not normally have a TRV, but, if it does, keep the TRV on
the maximum setting and adjust the room thermostat as explained with the instructions.
© Danfoss Climate Solutions | 01/2024 | AN000086405177en-010301(013R9399)
| General | Details |
|---|---|
| Name | Danfoss RAS-D2 Radiator Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.15 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide