With factory default settings the jumper is located on the central and  
uppermost pins, in which case the display shows the currently meas-  
ured room temperature value, while the notice “ROOM” appears in the  
bottom right corner of the display. In this case, the adjusted tempera-  
ture is visible only during the adjustment process, for approximately 6  
seconds after the last button has been pushed. By relocating the plug  
onto the bottommost and central pins the displayed temperature can  
be modified so that the display alternately shows the current room tem-  
perature and the adjusted temperature for 3-3 seconds, respectively.  
In this mode, the notices “ROOM” and “SET” are alternately shown  
under the currently displayed temperature in the bottom right corner of  
the display, indicating whether the display shows the room temperature  
or the adjusted temperature value.  
3.2 Selecting the Switching Sensitivity (Accuracy)  
The switching sensitivity of the thermostat can be selected or adjust-  
ed by the central jumper which detemines how much the thermostat  
switches the connected appliance on / off below / above the set tem-  
perature.  
With factory default settings the jumper is located on the central  
and uppermost pins, resulting in a switching sensitivity of ±0.2 °C.  
It can be modified to ±0.1 °C by relocating the jumper onto the  
- 8 -  
bottommost and central pins. A smaller switching sensitivity re-  
sults in steadier room temperature and therefore in higher comfort.  
The heat loss of the room (building) does not depend on the switching  
sensitivity.  
If higher comfort is needed, the switching sensitivity should be set so  
that it provides a steadier room temperature. On the other hand, please  
also take into account that the boiler should not switch on and off mul-  
tiple times in an hour’s time except at low outside temperatures (e.g.  
-10 °C), since the frequent on and off switches of the boiler reduce  
its efficiency and hence increases the gas consumption. We recom-  
mend using the ±0.1 °C switching sensitivity for heating systems with  
high thermal inertia (e.g. underfloor heating), and the ±0.2 °C switching  
sensitivity (factory default setting) for heating systems with low thermal  
inertia (e.g. flat panel radiators).  
You can read more about switching sensitivity in Chapter 5.  
3.3 Switching between the Heating and Cooling Mode  
The heating or the cooling mode of the thermostat can be  
selected by the right jumper. With factory default settings the  
jumper is located on the central and uppermost pins, which  
selects the heating mode. By relocating the jumper onto the  
- 9 -  
bottommost and central pins, the cooling mode can be selected.  
The output terminals of the receiver unit NO - COM and the zone  
outputs are turned on below the set temperature in heating  
mode, and they are turned off above the set temperature in  
cooling mode (taking the switching sensitivity into account).  
3.4. Calibration of the thermometer of the thermostat  
You can calibrate the thermometer of the appliance (to correct  
measured temperature). To this end all you have to do is change  
the position of the orange-colored potentiometer by a Phillips  
screwdriver. When you adjust the potentiometer clockwise then  
the displayed temperature will be lower than that measured  
initially, and when you adjust it anticlockwise the displayed  
temperature will be higher than that. The displayed temperature  
can be adjusted within a range of approx. ±4 °C.  
Correction of the displayed temperature takes place a few  
seconds after the adjustment.  
ATTENTION! If the modification of the basic settings was done  
after inserting the batteries and the modifications did not take ef-  
fect, please press the “RESET” button located on the main panel  
of the thermostat.  
- 10 -  
GeneralDetails
NameCOMPUTHERM Q5RF Multi Zone Wireless Digital Room Thermostat Instruction Manual
MakeCOMPUTHERM
LanguageEnglish
FiletypePDF (Download)
File size0.32 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual
COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual
COMPUTHERM Q20 Programmable Digital Room Thermostat Instruction Manual
COMPUTHERM Q20 Programmable Digital Room Thermostat Instruction Manual