Home > Honeywell Home > Honeywell Home RLV3150 Electric Thermostat

Honeywell Home RLV3150 Electric Thermostat

RLV3150  
ELECTRONIC THERMOSTAT  
USER GUIDE  
a resistive load over 12.5 A  
systems driven by a contactor or a  
relay (inductive load)  
APPLICATION  
This thermostat is designed to control  
an electric heating system such as a  
baseboard heater, a convector or a fan-  
forced heater.  
central heating systems  
Supplied Parts  
One (1) thermostat  
Two (2) 6-32 mounting screws  
Two (2) solderless connectors  
The thermostat cannot be used with the  
following:  
a resistive load under 2 A  
CONTROLS AND DISPLAY  
Backlit Screen  
Up button  
Down button  
Appears when the  
setpoint is displayed  
Temperature  
Appears when the  
thermostat is configured  
for a fan-forced heater  
(see page 3)  
Heating intensity  
indicator (the image  
disappears when  
heating is off)  
The settings are locked  
Fig. 1.  
33-00209EF-05  
GeneralDetails
NameHoneywell Home RLV3150 Electric Thermostat
MakeHoneywell Home
LanguageEnglish
FiletypePDF (Download)
File size1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell Home TH8320R1003-Uv VisionPRO 8000 with RedLINK Multistage Thermostat Installation Guide
Honeywell Home TH8320R1003-Uv VisionPRO 8000 with RedLINK Multistage Thermostat Installation Guide
Honeywell Home TH2110DH 1 Cool Programmable Digital Thermostat Installation Guide
Honeywell Home TH2110DH 1 Cool Programmable Digital Thermostat Installation Guide
Honeywell Home DT4R Wireless Room Thermostat User Guide
Honeywell Home DT4R Wireless Room Thermostat User Guide
Honeywell Home N100 Series Non Programmable Thermostat User Guide
Honeywell Home N100 Series Non Programmable Thermostat User Guide
Honeywell Home X1N Non Programmable Thermostat Installation Guide
Honeywell Home X1N Non Programmable Thermostat Installation Guide
Honeywell Home DT4M Wired Room Thermostat User Manual
Honeywell Home DT4M Wired Room Thermostat User Manual
Honeywell Home T834 Series Thermostat Owner’s Manual
Honeywell Home T834 Series Thermostat Owner’s Manual
Honeywell Home M38794 T10 and T10 plus Pro Smart Thermostat with RedLINK Installation Guide
Honeywell Home M38794 T10 and T10 plus Pro Smart Thermostat with RedLINK Installation Guide
Honeywell Home DT4 Channel Wired Room Thermostat Instruction Manual
Honeywell Home DT4 Channel Wired Room Thermostat Instruction Manual
Honeywell Home T10 Smart Home Thermostat Instructions
Honeywell Home T10 Smart Home Thermostat Instructions

Honeywell Home RLV3150 Electric Thermostat
Get the free PDF manual for the Honeywell Home RLV3150 Electric Thermostat and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Honeywell Home RLV3150 Electric Thermostat Overview

Summary of Contents

  • Page 1: Electronic thermostat user guide This thermostat is designed to control an electric heating system such as a baseboard heater, a convector or a fan-forced heater. Supplied parts include one thermostat, two 6-32 mounting screws, and two solderless connectors. The thermostat cannot be used with a resistive load under 2 A. Backlit screen features an up button and a down button. Heating intensity indicator appears when heating is on. The settings are locked.
  • Page 2: Installation guidelines for mounting the thermostat include several important steps. Loosen the screw underneath the thermostat and separate the faceplate from the wallplate. Turn off power to the heating system at the main power panel to avoid electrical shock. The installation must comply with local electrical codes. Do not install the thermostat in an area where it can be exposed to water or rain. Avoid locations with air drafts, dead air spots, or direct sunlight. Install the thermostat about 1.5 m (5 feet) high, on an inside wall facing the heater. Wire the thermostat according to the instructions provided. Mount the wallplate to the electrical box using the provided screws. The thermostat wires are not polarized; either wire can be connected to the load or to the power supply. Keep the air vents at the top and bottom of the thermostat clean and free from obstructions.
  • Page 3: The thermostat can be turned on by raising the setpoint using the Up button or turned off by lowering the setpoint using the Down button. If there is a protective film or sticker on the thermostat’s screen, peel it off. Apply power to the heating system. Verify the installation by checking that the heating system is operational. Connect the thermostat wires to the heating system and to the power supply. 2-wire installation instructions are provided. 4-wire installation instructions are provided. A figure illustrates the 2-wire and 4-wire installation.
  • Page 4: Configuration settings are located on the back of the faceplate. Factory settings are indicated inside gray cells. The thermostat buttons are disabled when the settings are locked. Place the fan setting to Yes if using a fan-forced heater to prevent premature burnout. Leave the fan setting at No for better temperature regulation if not using a fan-forced heater. The thermostat generally displays the room temperature. To display the set temperature, press the Up or Down button once. The setpoint temperature will remain on the screen for 5 seconds. To change the setpoint temperature, press the Up or Down button repeatedly until the desired temperature is displayed. The screen is backlit for 10 seconds when any button is pressed.
  • Page 5: When the last parameter is displayed, press the Up and Down buttons for three seconds to save any changes and exit the menu. Press the Up and Down buttons simultaneously for three seconds to enter the setup menu. Press the Up or Down button to change the option. Press the Up and Down buttons simultaneously and briefly to advance to the next parameter. If you do not press any button for 15 seconds, the thermostat will automatically save any changes you have made and will then return to its normal display. The minimum setpoint cannot be set higher than the value set for the maximum setpoint. The maximum setpoint cannot be set lower than the value set for the minimum setpoint. This is normal unless the thermostat is too hot to touch. Ensure that the heater capacity does not exceed the thermostat’s maximum load. The thermostat cannot be used below that rating.
  • Page 6: Specifications include supply voltage, minimum and maximum load, display range, setpoint range, and resolution. The supply voltage is 240 VAC at 60 Hz. The minimum load is 2 A (resistive only) or 500 W at 240 VAC. The maximum load is 12.5 A (resistive only) or 3000 W at 240 VAC. The display range is from 0°C to 50.0°C (32°F to 122°F). The setpoint range is from 5.0°C to 30.0°C (41°F to 86°F). The resolution is 0.5°C (1°F). The operating temperature range is 0°C to 50.0°C (32°F to 122°F). The storage temperature range is -20.0°C to 50.0°C (-4°F to 122°F). The product comes with a one-year limited warranty against defects in workmanship or materials.
  • Page 7: Customer assistance is available for questions about product installation, operation, or warranty. The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers for proper disposal. Correct disposal of end-of-life equipment helps prevent negative consequences for the environment and human health. This Class B digital apparatus complies with Canadian ICES-003. FCC statement is available online.
  • Page 8: Thermostat électronique guide de l'utilisateur Ce thermostat est conçu pour réguler un système de chauffage électrique tel qu'un chauffage de plinthe, un convecteur ou un chauffage à ventilation forcée. Un thermostat, deux vis de montage 6-32, deux connecteurs sans soudure. Le thermostat ne peut pas être utilisé dans les cas suivants : charge résistive inférieure à 2 A. Écran rétroéclairé. Bouton haut, bouton bas. Indicateur de l'intensité de chauffage. S'affiche lorsque le thermostat est configuré pour un chauffage à ventilation forcée.
  • Page 9: Installation directives Desserrer la vis qui se trouve sous le thermostat et séparer la plaque frontale de la plaque murale. Avertissement : Couper l'alimentation vers le système de chauffage au niveau du panneau d'alimentation principal pour éviter les chocs électriques. L'installation doit être conforme aux codes d'électricité locaux. Ne pas installer le thermostat dans une zone où il pourrait être exposé à de l'eau ou la pluie. Éviter les endroits où il y a des courants d'air, les zones mortes ou les endroits exposés à la lumière directe du soleil. Câbler le thermostat (voir « Câblage » à la page 11). Installer le thermostat à environ 1,5 m (5 pieds) de haut, sur un mur intérieur face à l'appareil de chauffage. Installer le thermostat sur un boîtier électrique. Des connecteurs sans soudure CO/ALR spéciaux doivent être utilisés si le thermostat sera connecté avec des fils en aluminium. Maintenir les évents en haut et en bas du thermostat propres et exempts d'obstructions.
  • Page 10: chauffage peut être mis en marche en augmentant le point de consigne à l'aide du bouton Haut ou éteint en réduisant le point de consigne à l'aide du bouton Bas. REMARQUE : Si l'écran du thermostat comporte un film protecteur ou un autocollant, le retirer. Mettre le système de chauffage sous tension. Vérifier l'installation en vérifiant que le système de câblage. Connecter les fils du thermostat au système de chauffage (charge) et à l'alimentation. Installation à 2 fils. Installation à 4 fils. Fig. 9. Installation à deux fils et à quatre fils.
  • Page 11: Réglages de configuration Les commutateurs de configuration sont à l'arrière de la plaque frontale. Les réglages d'usine sont à l'intérieur des cellules grises. Les boutons du thermostat sont désactivés et s'affiche sur l'écran lorsque les réglages sont verrouillés. Mettre sur Fan Yes si un chauffage à ventilation forcée est présent pour éviter l'épuisement prématuré du moteur. Laisser sur No pour obtenir une meilleure régulation de température si un chauffage à ventilation forcée n'est pas présent. Le thermostat affiche généralement la température ambiante. Pour afficher la température de consigne, appuyer une fois sur le bouton Haut ou Bas. La température de consigne s'affiche pendant 5 secondes. Pour ignorer la température de consigne de façon permanente, appuyer sur le bouton Haut ou Bas jusqu'à ce que la température désirée s'affiche.
  • Page 12: L'écran est rétroéclairé pendant 10 secondes lorsqu'un bouton quelconque est pressé. Appuyer simultanément sur les boutons Haut et Bas pendant trois secondes pour entrer dans le menu de configuration. Appuyer sur le bouton Haut ou Bas pour modifier l'option. Appuyer simultanément sur les boutons Haut et Bas brièvement pour passer au paramètre suivant. Si aucun bouton n'est pressé pendant 15 secondes, le thermostat enregistre automatiquement toutes les modifications effectuées. Le point de consigne minimum est de 5 °C - 30 °C (41 °F - 86 °F). Le point de consigne minimum ne peut pas être défini à une valeur supérieure à celle du point de consigne maximum. Le point de consigne maximum est de 5 °C - 30 °C (41 °F - 86 °F). Le point de consigne maximum ne peut pas être défini à une valeur inférieure à celle du point de consigne minimum.
  • Page 13: Problèmes et solutions Le thermostat est chaud. Ceci est normal. En fonctionnement normal, le boîtier du thermostat peut atteindre une température entre 35 °C (95 °F) et 40 °C (104 °F). La température affichée est erronée. Corriger si l’une des conditions suivantes existe : il y a un courant d’air à proximité, l’autocollant sur l’écran du thermostat n’a pas été enlevé, le thermostat est situé près ou au-dessus d’une source de chaleur. L’affichage disparaît et ne réapparaît qu’après quelques minutes. La protection thermique de la plinthe était temporairement ouverte. L’affichage est pâle. Le système de chauffage est inférieur à la charge minimale requise. Fiche technique Alimentation : 240 V c.a., 60 Hz Charge minimum : 2 A (résistive seulement), 500 W à 240 V c.a. Charge maximale : 12,5 A (résistive seulement), 3000 W à 240 V c.a. Plage d'affichage : 0 °C à 50,0 °C (32 °F à 122 °F) Plage de point de consigne : 5,0 °C à 30,0 °C (41 °F à 86 °F) Température de fonctionnement : 0 °C à 50,0 °C (32 °F à 122 °F) Mémoire permanente : Il est inutile de régler la température ou le thermostat après une panne de courant.
  • Page 14: Garantie limitée d'un an Resideo garantit ce produit, à l’exception des piles, contre tout défaut de pièce ou de main-d’œuvre, durant une période d'un an à partir de la date d’achat. En cas de défaillance ou de mauvais fonctionnement pendant la période de garantie, Resideo remplacera ou réparera le produit. La présente garantie ne couvre pas les frais de retrait ou de réinstallation. La responsabilité exclusive de Resideo se limite à réparer ou à remplacer le produit. Resideo n’est en aucun cas responsable des pertes ou dommages, y compris les dommages indirects ou accessoires. Cette garantie est la seule garantie expresse faite par Resideo pour ce produit. La durée de toute garantie implicite est limitée à la période d'un an de la présente garantie. La présente garantie donne au consommateur des droits spécifiques qui peuvent varier d’une province à l’autre. Pour toute question concernant la présente garantie, prière d’écrire aux Services à la clientèle de Resideo.