Select the desired
icon
or
5
Programming
menu
A
B
C
Icon
Description
Lower menu
Set the HOURS and DAY. Press again the SET-PROG (2) to
enter on lower menu and proceed to set. Hours and day are
automatically set if WiFi Box connected to an internet network.
From APP it is possible to synchronize the hours and the day of
the thermostat with your Tablet or Smartphone time.
Select with the buttons FORWARD (1) or BACK (3) the desired value (hours, minutes or
days) and with the UP(4) and DOWN (6) buttons select the values. Press the SET-
PROG (2) button to enter and return to the programming menu, press ESC-MODE (5) to
escape from the programming menu or wait 5 seconds to auto exit.
Set the temperature of DOMESTIC HOT WATER (when OT-
Bus connection available between WiFi Box and the boiler).
Press again the SET-PROG (2) to enter on lower menu and
proceed to set.
Select with UP (4) and DOWN (6) buttons the desired temperature value. Press the
SET-PROG (2) button to enter and return to the programming menu, press ESC-MODE
(5) to enter and esc from the programming menu or wait 5 seconds to auto exit.
dHW
They are shown in sequence the followings info (if value not available “- -” is shown):
tSEt = set-point flow temperature calculated by the thermostat.
tFLO = reading of the boiler flow sensor temperature.
trEt = reading of the boiler return sensor temperature.
tdH = reading of the boiler DHW sensor temperature.
tFLU = reading of the boiler flues sensor temperature.
tESt = reading of the boiler outdoor sensor temperature (fitted to the boiler or
communicated by the web).
Reading SENSORS/BOILER SETTINGS (when OT-Bus
connection available between WiFi Box and the boiler and if
the OT-Bus allow it). Press again the SET-PROG (2) to enter
on lower menu and proceed to read the values available.
InFO
MOdU = instantaneous percentage of modulation of boiler fan.
FLOr = instantaneous domestic hot water flow rate.
HOUr = hours worked in high condensation mode.
PrES = central heating system pressure.
tFL2 = reading of the heating flow sensor on second circuit