Home > BEOK CONTROLS > BEOK CONTROLS TDS75 Touch Screen Thermostat Instruction Manual
BEOK CONTROLS TDS75 Touch Screen Thermostat Instruction Manual
mode.
between manual mode and programmable
Defaulted Temp.
20℃
Period
Period Icon Defaulted Time
6:00
1
2
3
4
8:00
11:30
12:30
17:30
22:00
15℃
15℃
15℃
22℃
15℃
Week
Click the Add Device button in the upper right corner, or click Add Device.
Be sure to turn on your phone’s Bluetooth.
5
6
1
Only 2.4G status configuration can be added for WIFI access on mobile
phones (the name and password can only use numbers and letters,
not symbols).
8:00
22℃
Weekend
23:00
15℃
2
Remark:
(1) The defaulted temperature of period3 and period4 is the same as
period2. Please change it according to the request.
(2) When setting temperature is 00, this period is power off.
(3) How to check floor temp?
In the power on state, long press and hold
temp., OUT TEMP will display.
7. Advanced Setting
then press
to check floor
M
into
In the state of power-off, long press and hold M then press
advanced setting mode. Then press
to set relative item.
M
Factory
Default
Display
Code
Function
Setting And Options
0:Internal sensor
1:Floor sensor
2:Both internal sensor
and floor sensor
Sensor mode
SEN
0
Set temp. range
for floor sensor
OSV
DIF
42℃
5-99℃
Precision for
floor temp.
1-9℃
2℃
High limit temp.
for internal sensor
SVH
5-99℃
35℃
Low limit temp.
for internal sensor
5-99℃
5℃
SVL
ADJ
In the power off state, press up
and hold on for 10 seconds.
Check and calibrate
the actual room temp.
0.5℃accuracy
calibrate
Measure temp.
Frost-protection
Power memory
00:Off
01:On
FRE
PON
DFI
00
00
00:Off
01:On
Precision for
room temp.
1℃
0.5-3℃
08:Just display
00:Factory reset
FAC
08
Factory setting
Remark:
Antifreeze function: The thermostat is in the off state. When the indoor
temperature is lower than 5 °C, the electric valve is opened. When the
indoor temperature rises to 7 °C, the thermostat automatically turns off
the output.
Sensor error:
Please select the right sensor mode. If select the different mode or there
is error of sensor, Err will display on the LCD screen, the thermostat will
stop heating till the problem is solved.
Special note:
installing cable please choose: plumbing 1.5-2.5mm2 hard wire.
X. WIFI Connection
Smart Life APP Download
During configuration, the short blink is valid for 2 minutes (press the up
key for 10 seconds when shutting down the machine repeatedly: slow
flashing indicates AP network mode).
Android Download
IOS Download
| General | Details |
|---|---|
| Name | BEOK CONTROLS TDS75 Touch Screen Thermostat Instruction Manual |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.83 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual