Beca BHT-009 AI KnobThermostat User Guide
88.0
Informaꢀon & Technical Data
Power Supply:95 ~240 VAC, 50~60Hz
Current Load: 16A 3000W(electric heaꢀng)
20A 4000W (electric heaꢀng)
Sensor: NTC3950, 10K
Accuracy: ±1°C
Set Temp. Range: 5-35°C
Room Temp. Range: 5-70°C
Display Temp. Range: 5 ~ 70°C
Ambient Temp.: 0~ 45°C
Ambient Humidity:
5 ~ 95 % RH (Non Condensing)
Storage Temp.:-5~ 45°C
12.4
60.0±2mm
Power Consumpꢀon: <1. 5W
Timing Error: < 1%
Shell Material: PC +ABS ( Fireproof),PMMA
Installaꢀon Box:
86 * 86mm Square or European 60mm Round Box
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2
Protecꢀon Class: IP20
12.0
Buꢁons: Knob + touch buꢁon
50.0
Installaꢀon
Your thermostat is suitable for installaꢀon within a standard 86mm paꢁress box or European 60mm paꢁress box.
4. Installaꢀon completed
1. Accurately connect the power cable
to the power terminal box.
2. Fix the mounꢀng plate on the casseꢁe
with a screwdriver through two screws.
3. Hang the control panel onto the
mounꢀng plate
During Power On
Operaꢀon
1.Power On/off: Press the knob to turn the thermostat on/off.
2.Manual & Programmable
Press the icon “ ” again, the temperature seꢂng will flash, set the temperature
turning the knob;This completes the seꢂng of periods1.
In the same way, complete the seꢂngs of periods2, 3, 4,5and 6.Press the icon “
once more to enter the Saturday schedule seꢂngs (you will see the ⑥ of the screen).
Repeat the above process to set the period and temp. and ⑦ schedule.
Press the icon “ ” once more to confirm and exit.
”
Touch to change between manual mode
In manual mode, will show on the display,
and programme mode
.
In programmable mode, will show on the display.
3.Seꢂng Temperature
In the programming mode, the temperature seꢂng and ꢀme seꢂng will be locked.
If the user wants to adjust, he must first adjust the thermostat to manual mode by
pressing the“ ”key.
Default seꢂngs for program schedule
MON. -FRI.
SAT.
SUN.
Time
(①②③④⑤ shows on scteen)
(⑥ shows on scteen)
(⑦ shows on scteen)
display
In the manual mode, pthe desired temperature can be set by turning the knob.
TIME
TEMP.
20
ON TIME
6:00~8:00
TEMP.
ON TIME
6:00~8:00
TEMP.
4.Adjusꢀng/Seꢂng the Clock
Press“ ”to set minute, hour and weekday. and adjust the values by turning the knob.
Press “ ”once more to confirm and exit.
Period 1
Period 2
Period 3
Period 4
Period 5
Period 6
6:00~8:00
20
20
20
20
20
15
20
20
20
20
20
15
8:00~11:30
11:30~13:30
13:30~17:00
17:00~22:00
22:00~6:00
15
8:00~11:30
11:30~13:00
13:30~17:00
17:00~22:00
22:00~6:00
8:00~11:30
11:30~13:00
13:30~17:00
17:00~22:00
22:00~6:00
15
5.Locking your Thermostat
Press and hold the“ ”and“ ”for 5 seconds to lock/unlock your thermostat.
In item 3 of high senior opꢀons, you can select full lock or half lock.
15
22
15
6.Adjusꢀng/Seꢂng the Programmable Schedules
Press icon“ ” four ꢀmes in a row. You can see " ① ② ③ ④ ⑤ " and“ ”, a
nd the minutes of ꢀme are flashing.
A separate schedule may be set for weekdays (Mon – Fri) and for weekends (Sat or Sun).
7.Checking the Temperature of Floor Sensor
Press and hold the“ ” arrow for 5 seconds to display the temp. of floor sensor. If no
external sensor is connected, the thermostat will display "Er".Note: Do not use third-
party external sensors, the temperature will be incorrect.
Turning the knob to set the minutes;
Press the icon “ ” again, the hour of the ꢀme will flash, set the hour by turning
the knob;
8.Seꢂng the Funcꢀons and Opꢀons
During power off, Press and hold “ ”and “ ” for 8 sec. in the order to reach system funcꢀon. Then press “ ” to scroll through the available funcꢀons,and use turning the knob
to change the available opꢀons. All seꢂngs are confirmed automaꢀcally.
Code
Function
Setting and options
Default
Code
Function
Setting and options
Default
1
Temperature compensation
-9 to 9 ℃
-3
9
High temp. protection setting. 25-70℃
45
Daytime display brightness
(6:00-22:00)
When set to 0, the device will run for 10
seconds after inactivity.
The screen will go completely off with no
display.
2
3
Deadzone Temp.
1-5℃
01
01
10
03
0-8
00:All buttons are locked except power button.
01:All buttons are locked.
Brightness display brightness
(22:00-06:00)
Button Locking
11
12
13
01
1
Screen line standby brightness 1-5
In: Internal Sensor(to control the temp.)
Ou: External Sensor (to control the temp.)
AL: Internal&External Sensor (Internal sensor to
control the temp., external sensor to limit the
temp.)
Power collection_x0002_working
4
Sensor typer
AL
0:24V,1:100V, 2:110V, 3:120V, 4:220V, 5:230V
4
voltage
Month
Days
14
15
Show only
5
6
Min.Set Temp.
Max.Set Temp.
5-15℃
05
35
Show only
15-45℃
00: No factory reset;
01: Factory reset
00:Display set Temp. and Room Temp.
01:Only display set Temp.
0-10℃
16
17
Reset
00
7
8
Temp. display
00
00
Low temp. protection setting.
Version number
U2
| General | Details |
|---|---|
| Name | Beca BHT-009 AI KnobThermostat User Guide |
| Make | BECA |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.31 MB |

Beca BHT-9000 Thermostat User Guide

beca BAC-005 Series Thermostat User Guide

Beca BHT-6000 Series Round Thermostat User Guide

Beca BAC-1000 Series WiFi Thermostat User Guide

Beca BHT-002 Electric Heating Wifi Thermostat User Guide

Beca BHT-008 Heating Thermostat User Guide

Beca BHT-7000 Smart Knob Thermostat User Manual

Beca BAC-006 Zigbee Thermostat User Guide

Beca BHT-006 Series Thermostat User Manual

Beca BHP-8000 C Room Thermostat User Guide