Home > Ariston > ARISTON 3319126 CUBE S NET Wi-Fi Thermostat User Manual

ARISTON 3319126 CUBE S NET Wi-Fi Thermostat User Manual

Technical specifications  
BridgeNet® BUS  
8 to 24V max; lithium ion battery  
Power supply  
Battery  
3.7 VDC  
500 mAh  
Current draw  
≤30mA  
Operating temperature  
Storage temperature with battery  
Storage temperature without battery  
Humidity  
-0 to 40°C  
-10 to 45°C  
-20 to 70°C  
20% RH to 80% RH  
+/- 0.5°C  
Temperature reading precision  
Bus wire length and cross-sectional area  
NOTE: TO AVOID INTERFERENCE PROBLEMS,  
USE A SHIELDED CABLE OR TWISTED PAIR CABLE.  
max. 50 m  
ø min. 0.5 mm²  
Insulation class  
Protection rating  
Dimensions  
III  
IP 20  
103mm x 103mm x 19.1mm  
Frequency band used  
2400 MHz - 2483.5 MHz  
Maximum power in the band  
Wi-Fi channels  
+19 dBm  
1-13  
Product card (with BridgeNet bus system only)  
Supplier name  
ARISTON  
Supplier identification model  
CUBE S NET  
Temperature control class  
V
Energy efficiency contribution (%) for space heating  
With an optional external sensor or internet weather data:  
Temperature control class  
+3%  
VI  
Energy efficiency contribution (%) for space heating  
In a system with 3 zones with 2 room sensors:  
Temperature control class  
+4%  
VIII  
Energy efficiency contribution (%) for space heating  
+5%  
EN / 19  