Aprilaire S86N MUPR Multi Stage Universal Thermostat Owner’s Manual
PROGRESSIVE RECOVERY
HOW TO MODIFY PROGRAM SCHEDULES
1. From the Schedule option in the
Main Menu, you can turn the
schedule On or Off, and make
changes to the scheduleꢀ
The Progressive Recovery feature allows Pre-Heating or Pre-Cooling PRIOR to a scheduled
event in order to reach the desired temperature at the start of that scheduled eventꢀ EXAMPLE:
According to TABLE 2, the Wake time is 6:00 am, the Wake heat set point is 70°F and the Sleep
set point is 62°Fꢀ The heat will turn on prior to 6:00 am so that the temperature reaches 70°F by
the time the Wake event beginsꢀ
Main Menu
Mode
Fan
Modify: The event start time,
temperature, fan mode, and
controlling sensor (if installed)
can be adjusted for each event
of each dayꢀ
1
Hold
Schedule
Heat Blast
On/Off: When the Schedule
is turned Off the thermostat
will continue to control at the
current temperature setting until
2
3
4
Schedule
Modify
On
Modify Day
All Days
Wake
Next
adjusted with
and
ꢀ
2. Select Modify to change default
schedule settingsꢀ
Weekdays
Weekends
Monday
Start
Heat
Cool
Fan
6:00a
70°
3. Select the group of days or day
you would like to modifyꢀ
70°
Tuesday
Auto
4. Adjust Wake details (Start, Heat,
Cool, Fan, and/or select Next to
proceedꢀ
22
23
| General | Details |
|---|---|
| Name | Aprilaire S86N MUPR Multi Stage Universal Thermostat Owner’s Manual |
| Make | Aprilaire |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.44 MB |

Aprilaire 8570 Premium Programmable Thermostat Instruction Manual

Aprilaire 8538 Digital Heat Cool Thermostat Owner’s Manual

AprilAire S86W MUPR WiFi Thermostat User Guide

Aprilaire S86N MU Multi Stage Universal Thermostat Instruction Manual

Aprilaire S86WMUPR Programmable Wi-Fi Multi Stage Universal Thermostat Installation Guide